EPA WTC interim report comments, 2003

Machine-extracted title · confidence 28%

Comments on EPA interim report regarding World Trade Center collapse from 2003.

NYC-WTC_000251148–000251575
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

L: EPA refusal to use electron microscopes for dust testing - 225

by the old PLM light microscope method, a newly released study by EPA reveals that EPA itself performed TEM analyses of dusts inside a building at 110 Liberty St. to assess cleaning methods. This was the first time that EPA used TEM analyses of dusts related to the WTC, with the exception of using TEM dust analyses in its own building at 290 Broadway a few days after 9/11.

EPA’s use of TEM for the 110 Liberty St. study constitutes an admission by EPA that TEM testing is necessary to detect the presence of asbestos laden dust and the efficiency of any cleaning procedure. See Section G for a more complete discussion of EPA’s WTC dust cleaning study at 110 Liberty St.’"

Criticisms and press coverage of EPA not using TEM analyses for WTC dust

EPA Region 2 is apparently currently claiming that they were unaware of the need to use TEM and the other better test methods, and that there was a training problem;

3/19/03 With backing from top agency enforcement officials, EPA's research office has begun an initiative to ensure the uniformity of the agency's analytical methods across regions and program offices.

The effort was prompted by concerns following Region Il's investigation of environmental hazards at the World Trade Center site and their consistency with asbestos measures used by EPA Region VIII in Libby, MT.

“When the agency uses different measures, then people can begin to ascribe motives, so the Administrator prompted us to look into this," according to EPA research chief and science advisor Paul Gilman. “It's hard to have credible decisions without credible data,"

An EPA official adds “this is an effort to make the science better, to put good science out there for the regulated community to use.... new group that will examine the creation, verification and validation of environmental methods and training across the agency.

[From Inside EPA Environmental Policy Alert, 3/19/03, www.insideepa.com ]

I publically criticized EPA’s failure to use TEM analyses for bulk WTC dust, failure to take wipe and/or microvacuum samples of hard smooth surfaces inside buildings, and failure to use EPA’s ultrasonification extraction method for carpets and other porous materials early in the WTC investigation through memoranda which were received by relevant staff at Region 2. Their first alert of the need to use TEM came on 9/12/01 from Region 8. It is absurd to claim that there was any lack of training or knowledge of EPA requirements.

Below are excerpts of press on the TEM v. PLM issue, as well as early criticisms of EPA;

NYC-WTC_000251381

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000251381Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →