NYC 9/11 Public Portal Document
assessing WTC ambient data.) Since this was done very quickly during an
emergency situation, these benchmarks were not subjected to peer review.
In addition to not knowing the health impacts of certain individual pollutants,
information was not available on the cumulative or synergistic impacts of being
exposed to several pollutants at once. For example, one medical expert suggested
there may be a synergistic effect between PAHs and asbestos, since PAHs
resemble cigarette tar. Studies have shown the lung cancer risk from exposure to
asbestos is increased exponentially for cigarette smokers. In addition, this expert
noted that the combination of high pH and the small shards of glass found in
WTC dust could have had a synergistic impact on the acute respiratory symptoms
that many people experienced.
There were limitations with all three methods used to analyze asbestos
concentrations in the ambient air and bulk dust in Lower Manhattan. These
limitations, which were not noted in EPA’s press releases, restricted EPA’s ability
to make definitive assessments about the health risks posed by asbestos.
However, even with these limitations, sufficient data existed to identify the
presence of asbestos in the dust and ambient air, and to warrant that persons
working around the dust take necessary precautions to not inhale the dust. The
three methods used and their limitations follow:
• Transmission Electron Microscopy (TEM) is a sensitive method generally
used to analyze air samples collected from a relatively clean indoor
environment. At the WTC site, many samples could not be analyzed because
the filters being used to collect asbestos were overloaded with particulates.
For example, 24 of the 69 samples collected as of September 17 could not be
analyzed because the filters were overloaded.
• Phase Contrast Microscopy (PCM), which was used to analyze asbestos
concentrations in ambient air beginning September 18, can only Count fibers
in the filter greater than 5 micrometers in length. A study at the WTC site
found that the majority of the asbestos fibers at the site were less than
5 micrometers in length.
• Polarized Light Microscopy (PLM) was used to measure asbestos in bulk dust.
This method is primarily an estimation method that is not very precise, and
has a detection limit of 1 percent. Therefore, using this method against a strict
benchmark is not reliable.
According to EPA, essentially all outdoor areas at the WTC site were vacuumed,
and the detection methods did not impact the action actually taken to remove the
dust from outdoor areas. See Appendix E for a summary of EPA’s outdoor air
asbestos sampling results.
13 Report No. 2003-P-00012
NYC-WTC_000145368
OCR can misread numbers and units. Confirm readings against the page image before using them.