EPA WTC interim report comments, 2003

Machine-extracted title · confidence 28%

Comments on EPA interim report regarding World Trade Center collapse from 2003.

NYC-WTC_000251148–000251575
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

S: Failure to test for other toxins in cleanup - 310

Three sites (Church/Warren, WTC East and the paired Museum-North and Museum- South) were located within 0.5-0.75 km of the WTC and were expected to be most immediately impacted by the contaminant plume. The windows at these sites directly faced the WTC, with the exception of Museum-South that faced directly away. The remaining four Manhattan sites (Worth/ Broadway, Canal/Broadway, NYU and Union Square) were located along a north-south transect northward from the WTC. The furthest site. Union Square, was -4 km from the WTC. The Brooklyn location, which served as a control site, was approximately 3.5 km away from the WTC. The last time of cleaning was before September 11, 2001.

Total PCB concentrations decreased with increasing distance from the WTC site (see Table 1) with the highest concentrations measured at the three sites near the WTC. The highest PCB concentrations were measured in the two samples from the Museum site, a building located just south of the WTC, the direction of prevailing winds for several days after September 11th. These concentrations were nearly three times greater than the Church/Warren site, which was located closer to the WTC than the Museum site, but to the north. Paired samples were collected on the north (Museum North Side) and south (Museum South Si de) facing windows at the Museum site, corresponding to the sides of the building that directly face and face away from the WTC, respectively. The total PCB concentration on the Museum North windows were about 10 % greater than south facing windows. This is a minimal difference and indicates that the atmospheric plume was relatively well mixed at close range.

Location [Total] PCB Distance from (ng/m^) WTC (km) Museum North Si de 1398 0.75 Museum South Si de 1260 0.75 Church/Warren 404 0.5 Park Row/Spruce 105 0.75 Worth/Broadway Street 511 1 Canal/Broadway Street 107 1.5

NYU 10 2.75 Union Square 89 3.5 Brooklyn 82 4

[POLYCHLORINATED BIPHENYL (PCB) CONCENTRATIONS IN ATMOSPHERICALLY DERIVED ORGANIC FILMS FROM LOWER MANHATTAN AFTER SEPTEMBER 11, 2001, Craig M. Butt, Jennifer Truong, Miriam L. Diamond and Gary A. Stern, FORMATION AND SOURCES: FIELD CASES, ORGANOHALOGEN COMPOUNDS Vol. 59 (2002) 219]

NYC-WTC_000251466

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000251466Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →