Congeners in water samples were also found, also with no locations or detect status. No PCB Congener data was available for bulk dust or air samples.

PCBs-Totals in dust wipe samples were reported for four (4) samples at three (3) locations, including Manahattan Community College (two (2) samples on Sept 28), PS 234-Chambers & Greenwich St (Sept 29), and Stuyvesant High School (Sept 28). In all four of these samples, PCBs-Totals were not detected at 0 ng/100 cm ’ or <5 ng/100 cm^

To date, PCBs-Totals in air samples were reported for twelve (12) Lower Manhattan locations on nine (9) sampling dates. Results have been recorded in the database for samples taken up to October 26*. Detected values were reported in six (6) of the twelve (12) sites, as listed in Table 13 and illustrated in Figure 8. PCBs-Totals in air were not detected at Location E - Liberty & South End Ave, Location F-Vesey & West St, Location P - Albany & South End Ave, Location R - EPA TAGA Bus, and Location S - Rector Pl & South End Ave.

The WTC - Building 5 SW and Location A - Barclay & West Broadway sites had the highest PCBs- Totals in air results. The highest reported value was 153 ng/m^ on October 2“* at the WTC Building 5 SW site. For these two (2) sites, the correlation coefficient is low at 0.0351, indicating different patterns of change. Comparison of the results from the Location B - Church & Dey St and WTC - Building 5 SW sites through October 15* reveals a correlation coefficient of 0.8690.

The linear fit lines in Figure 9 indicates a steady decrease in Total PCBs at the WTC Building 5 SW, Location B, and Location A sites. At all of the sites, except WTC-Building 5 SW, the most recent results from October 15*, 18*, and 26* are all zero (0) or undetected.

Page 38 of 52

CITY_21MC100_009029260

NYC-WTC_000303051

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000303051Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000250638

Draft EPA SIA#14 report on environmental data for World Trade Center site.

Similar indexed content

NYC-WTC_000263437

SIA#14 draft report prepared for EPA Office of Emergency/Remedial Response.

Similar indexed content

NYC-WTC_000186193

Draft environmental data report for the World Trade Center site prepared by IT Corporation for the EPA in November 2001.

Similar indexed content

NYC-WTC_000245917

Draft auditing data for World Trade Center-related environmental assessment; NYC ops.

Similar indexed content

Compare copies and versions →