NYC-WTC_000307170
Discussion on TEM detection of asbestos fibers and regulatory limits referenced.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Lab report discussing TEM vs optical microscopy and regulatory asbestos limits.
NYC-WTC_000437306–000437311OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
microscopy an outdated technology for the comminution. The NTOSH 7400 Method spectrum for amosite asbestos is shown in evaluation of occupational exposures to clearly, states that fibers thinner than 0.25 Figure 1. asbestos either in factories or in abatement micrometers will not be detected." TEM also has an analytical tool called jobs. The most recent EPA guidance Differences between opSicaJ microscopy selected area electron diffraction (SAED). document. The Purple Book, states that and TEM. The gulf between the optical This tool allows for the visualization of variations over time in levels of PCM- microscope and TEM is significant. In The the crystalline pattern of the fiber. The measured fibers and actual asbestos fibers Purple Book, the EPA compares analytical pattern for chrysotile is quite distinct from appear to be correlated.^ sensitivity by listing the diameter of fibers the amphiboles. Non-crystalline fibers such Fibers are different in buildings. each method can ty'pically resolve. The as cellulose and fiberglass, which are Asbestos fibers appear to be smaller (fewer results indicate that TEM is far superior often confused with asbestos under other bundles) and make up a smaller fraction to other methods. Interestingly, scanning methods, can be excluded through SAED. Characteristic patterns for amosite asbestos reveal strong silicon and iron peaks found i in amosite. BER CHI FIBER SIZE DISTRIBUTION IN AIR AND LUNG TISSUE With an understanding of the analytical methods, the relationship of the visible to invisible fibers in air samples and lung tissue can be explored, as can the question of whether an estimate of the invisible portion can be made from the PCM fiber count. To fully appreciate how different the of airborne fibers. The slow degradation electron microscopy (SEM) has resolution technologies are, note the frequency of asbestos-containing materials (ACM) in powers only moderately better than PCM. distribution of fibers on the standard ventilation airstreams or around sources of The differences between optical and material filters supplied by the National vibration in buildings has a tendency to electron microscopy can also be seen Bureau of Standards for air sample analysis produce much thinner and shorter fibers regarding specificity. The eyepieces used by TEM, (see Figure 2).' The heaviest than the physical removal of asbestos for ail optical methods—the Porton reticle, distribution of fibers in the samples is from ceilings and mechanical systems the Patterson globe reticle and the neve approximately 1 micrometer in length, during abatement.’ The latter method Walton Beckett graticule—are solely although virtually none of the fibers are produces asbestos fibers embedded in a designed for counting, not identification. above 5 micrometers in length. mati’ix of the insulation material, released Both TEM and SEM are capable of analyz /ishestosfihers in the air In 1983, in an environment where high-efficiency ing fibers that distinguish asbestos from researcher CY Hwang sampled the air in particulate air (HEPA) ventilation units are non-asbestos. Scanning and transmission underground mines in South Africa and at constantly purging the air. In a building, the scopes are capable of employing energy an open pit in Canada with its associated erosion process releases extremely small dispersive spectrometry that measures mills.* Hwang used TEM to measure trae amounts of asbestos fibers that have the X-rays being released by fibers. The energy diameter and true length of the fibers, (see potential to remain airborne longer than level of these X-rays is characteristic for Thble 1). He found that the distribution in an abatement project. While airborne, the each element found in the fiber. A spectrum was non-Gaussian and that the median fibers can be further reduced in diameter can be created for each fiber showing diameters of the crocidolite and chrysotile and length through a process called the main elemental components. A typical fibers would render them invisible to the optical microscope. The aspect ratios he reported were much greater than the 3-1 ratio used by OSHA. All of the median lengths were less than OSHA’s 5 m.icrometersrequirement. In 1984, Marconi compared results of light microscopy and TEM in evaluating occupational exposures to airborne chrysotile.* He found that 10 percent of all fibers greater than 5 micrometers in length had diameters rendering them invisible to the light scope. He reported that the ratio of short to long fibers ranged from 0.8 to 3.6 micrometers, depending on the occupational process. This data indicates that in some workplaces
ASBESTOS ISSUES ‘89—MARCH
CITY_21MC100_003254592
NYC-WTC_000437307
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000307170
Discussion on TEM detection of asbestos fibers and regulatory limits referenced.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000337538
Academic article on TEM detection limits for asbestos fibers and regulatory context.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000306672
Discussion on TEM vs optical microscopy for asbestos fiber detection and history.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318625
Overview of TEM vs optical microscopy for asbestos fiber measurement and historical context.
15 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000289570
Glossary and reference material on asbestos terms and regulations used for lab context.
13 shared non-person entities · 1 shared topics · similarity 0.959
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000275365
Omitted EPA IRIS draft reference on asbestos fibers and mesothelioma discussion.
7 shared non-person entities · 1 shared topics · similarity 0.944
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000337374
Omitted-from report: excerpts discussing asbestos fiber types and mesothelioma implications.
7 shared non-person entities · 1 shared topics · similarity 0.943
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000450586
PCM asbestos method overview and regulatory limits for fibers.
11 shared non-person entities · 1 shared topics · similarity 0.940
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451078
Asbestos and other fibers by PCM/TEM method 7400; evaluation guidelines included.
11 shared non-person entities · 1 shared topics · similarity 0.940
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434430
PCM/NIOSH/ACGIH reference for asbestos fiber measurement; method 7400 with detection limits.
11 shared non-person entities · 1 shared topics · similarity 0.940
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433590
PCM analysis of asbestos and other fibers with reference thresholds.
11 shared non-person entities · 1 shared topics · similarity 0.940
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442815
Fiber analysis method overview and PCM/NIOSH/OSHA references for asbestos.
11 shared non-person entities · 1 shared topics · similarity 0.940
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000306672
Discussion on TEM vs optical microscopy for asbestos fiber detection and history.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000307170
Discussion on TEM detection of asbestos fibers and regulatory limits referenced.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000337538
Academic article on TEM detection limits for asbestos fibers and regulatory context.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318625
Overview of TEM vs optical microscopy for asbestos fiber measurement and historical context.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318598
Draft guidance document on TEM/PCM analysis and air testing for asbestos.
Similarity score 0.972 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000279330
First draft outlining TEM/PCM methods for asbestos identification and analysis.
Similarity score 0.969 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000307170
Discussion on TEM detection of asbestos fibers and regulatory limits referenced.
Similar indexed content
NYC-WTC_000337538
Academic article on TEM detection limits for asbestos fibers and regulatory context.
Similar indexed content
NYC-WTC_000306672
Discussion on TEM vs optical microscopy for asbestos fiber detection and history.
Similar indexed content
NYC-WTC_000318625
Overview of TEM vs optical microscopy for asbestos fiber measurement and historical context.
Similar indexed content
NYC-WTC_000289570
Glossary and reference material on asbestos terms and regulations used for lab context.
Similar indexed content