NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 6 pages

TEM vs optical fiber analysis, asbestos

Machine-extracted title · confidence 28%

Academic article on TEM detection limits for asbestos fibers and regulatory context.

NYC-WTC_000337538–000337543
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

microscopy an outdated technology for the comminution. The NIOSH 7400 Method spectrum for amosite asbestos is shown in evaluation of occupational exposures to clearly, states that fibers thinner than 0.25 Figure 1. asbestos either in factories or in abatement micrometers will not be detected.*’ TEM also has an analytical tool called jobs. The most recent EPA guidance Differences between optical microscopy selected area electron diffraction (SAED). document. The Purple Book, states that and TEM. The gulf between the optical This tool allows for the visualization of variations over time in levels of PCM- microscope and TEM is significant. In The the crystalline pattern of the fiber. The measured fibens and actual asbestos fibers Purple Book, the EPA compares analytical pattern for chrysotile is quite distinct from appear to be correlated.'' sensitivity by listing the diameter of fibers the amphiboles. Non-crystalline fibers such Fibers are different in buildings. each method can typically resolve. The as cellulose and fiberglass, which are Asbestos fibers appear to be smaller (fewer results indicate that TEM is far superior often confused with asbestos under other bundles) and make up a smaller fraction to other methods. Interestingly, scanning methods, can be excluded through SAED. Characteristic patterns for amosite asbestos reveal strong silicon and iron peaks found

REPORTE^D^BY ITirQ in amosite. - W FIBER SIZE DISTRIBUTION IN AIR rEMANALYSES AND LUNGTISSUE Asbestos Median! Meciiah With an understanding of the analytical Dia. (pm, Lengl methods, the relationship of the visible to . .. Crocidolite’ , 0 ■ H a invisible fibers in air samples and lung tissue can be explored, as can the question 2.53 ■0.55 i of whether an estimate of the invisible portion can be made from the PCM fiber count. To fully appreciate how different the of airborne fibers. The slow degradation electron microscopy (SEM) has resolution technologies are, note the frequency of asbestos-containing materials (ACM) in powers only moderately better than PCM. distribution of fibers on the standard ventilation airstreams or around sources of The differences between optical and material filters supplied by the National vibration in buildings has a tendency to electron microscopy can also be seen Bureau of Standards for air sample analysis produce much thinner and shorter fibers regarding specificity. The eyepieces used by TEM, (see Figure 2).’ The heaviest than the physical removal of asbestos for all optical methods—the Porton reticle, distribution of fibers in the samples is from ceilings and mechanical systems the Patterson globe reticle and the new approximately 1 micrometer in length, during abatement.'^ The latter method Walton Beckett graticule—are solely although virtually none of the fibers arc produces asbestos fibers embedded in a designed for counting, not identification. above 5 micrometers in length. matrix of the insulation material, released Both TEM and SEM are capable of analyz­ Asbestosfibers in the air. In 1983, in an environment where high-efficiency ing fibers that distinguish asbestos from researcher CY Hwang sampled the air in particulate air (HEPA) ventilation units are non-asbestos. Scanning and transmission underground mines in South Africa and al constantly purging the air. In a building, the scopes are capable of employing energy an open pit in Canada with its associated erosion process releases extremely small dispersive spectrometry that measures mills.” Hwang used TEM to measure true amounts of asbestos fibers that have the X-rays being released by fibers. The energy diameter and true length of the fibers, (see potential to remain airborne longer than level of these X-rays is characteristic for Thble 1). He found that the distribution in an abatement project. While airborne, the each element found in the fiber. A spectrum was non-Gaussian and that the median fibers can be further reduced in diameter can be created for each fiber showing diameters of the crocidolite and chrysotile and length through a process called the main elemental components. A typical fibers would render them invisible to the optical microscope. The aspect ratios he reported were much greater than the HIM 3-1 ratio used by OSHA. All of the median lengths were less than OSHA’s 5 .-’.i xTEM MEASUHE micrometers requirement. In 1984, Marconi air^rneaeS^stos compared results of light microscopy and

ANafe TEM in evaluating occupational exposures to airborne chrysotile.’ He found that 10 percent of all fibers greater than 5 micrometers in length had diameters rendering them invisible to the light scope. He reported that the ratio of short to long fibers ranged from 0.8 to 3.6 micrometers, depending on the occupational process. This data indicates that in some workplaces

ASBESTOS ISSUES '89—MARCH

CITY_21MC100_003062653

NYC-WTC_000337539

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000337539Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Small fiber study: TEM vs OSC

NYC-WTC_000318625

Overview of TEM vs optical microscopy for asbestos fiber measurement and historical context.

Similar indexed content

Compare copies and versions →