there may be four times as many fibers microscopy. More importantly, they found more than is found in the general popula- invisible to PCM as there are visible to it. that of those fibers having a length greater tion, while the mean aspect ratio for the In 1979, researchers Dement and Harris than 5 micrometers, 75 percent would still crocidolite fibers found was 48 and the also used TEM to evaluate the size and be invisible to optical microscopy. mean for the amosite fibers was 34. diameter of asbestos fibers in asbestos Fibers in lung tissue. The presence Of the crocidolite fibers, 17 percent mills."’ Their data compared favorably of short fibers in the air of workplaces were less than the OSHA fiber length of to that of Hwang, as indicated in Table says nothing about the health risks of 5 micrometers and 55 percent had width.s 2. Dement and Harris consider 0.3 these smaller fibers. Pooley and Ranson below 0.1 micrometers, rendering them invisible to optical microscopy. This study contradicted the hypothesis that states the highest aspect ratios are seen with the longest fibers. The study also confirmed that crocidolite fibers—considered by most authorities to be the strongest inducer of mesothelioma—are shorterand thinner than amosite fibers found in the same lung tissue.
MEDICAL SIGNIFICANCE OF SHORT FIBERS The presence of short fibers in the lung
MB is more important than the presence of the fibers in any of the well-documented disease processes associated with asbestos.
Ia It is important, as George A. Peters points out in his Sourcebook on Asbestos Diseases, to differentiate between asbestosis and cancer. Initial research gave credence to a widely held belief that short fibers were relatively harmless. In a copy of Patty's Industrial Hygiene, George W. Wright A typical spectrum for amosite asbestos. indicates, “asbestos fibers shorter than 5 to lO microns, whether coated or naked, micrometers to be the limit of resolution compared the results of asbestos fiber dust behave essentially like inert particles .. for optical microscopy. counts from necropsy material using an when the fibers do not exceed 5 micrometers Another major study conducted in 1984 analytical electron microscope and a light in length, tumor production, if it does occur, by Rood and Streeter analyzed 14 air microscope.'^ Their results indicated that is not statistically significant.” ’’ samples by TEM that had been collected the light microscope visualizes only 5 Most current research pursues one or from the air of textile mills." They counted percent crocidolite, 26.5 percent amosite more of the following characteristics of a minimum of 100 fibers per TEM grid. In and 0.14 percent chrysotile, leading to the asbesto,s fibers: order to be counted, however, all fibers had following quote, “Therefore, although it is • fiber length; to be less than 3 micrometers in diameter. possible, using electron microscopy (EM), • fiber diameter; Their results indicate: to predict the asbestos fiber count that • fiber number; and •the frequency distribution was would be obtained by light microscopy, the • fiber retention. approximately log-nonnal; reverse prediction cannot be made.” Complexities ofthe disease process. One • the geometric mean diameter was 0.08 In 1984, Andrew Churg and Barry Wiggs of the most basic concepts taught in every micrometers; confirmed what Pooley and Ranson had asbestos worker course in this country is •the median length was 1.6 found: optical microscopy is not capable that asbestos fibers of a particular length micrometers; of detecting the majority of amphibole (generally between 5 and 10 micrometers) •of all fibers counted, 60 percent had asbestos fibers in the lung.'^ Working with are engulfed by macrophages in the alveoli diameters less than 0.2 micrometers; the lung tissues from 10 patients with of the lung causing them to rupture and and amphibole malignant pleural mesothelioma, release hydrolytic enzymes. This is a well- • a total of 93 percent had diameters less they identified the type, size and number of documented process but it is only associated than 0.3 micrometers. amphibole asbestos fibers. In eight of these with asbestosis, not cancers. Their data indicate that 60 percent of patients who were not long time insulators. The process by which asbestos fibers all the fibers in the air of the mills would the mean number of amosite fibers found in cause or promote cancer is not well have been invisible to SEM, while 93 the lung tissue was 2.3 million per gram of understood. Outside our knowledge of percent would have been invisible to optical dry lung. This is approximately 250 times asbestosis, most other asbestos-related
ASBESTOS ISSUES '89—MARCH
CITY_21MC100_003062654
NYC-WTC_000337540
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000318625
Overview of TEM vs optical microscopy for asbestos fiber measurement and historical context.
16 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000289570
Glossary and reference material on asbestos terms and regulations used for lab context.
13 shared non-person entities · 1 shared topics · similarity 0.958
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000275365
Omitted EPA IRIS draft reference on asbestos fibers and mesothelioma discussion.
7 shared non-person entities · 1 shared topics · similarity 0.944
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000337374
Omitted-from report: excerpts discussing asbestos fiber types and mesothelioma implications.
7 shared non-person entities · 1 shared topics · similarity 0.943
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000307170
Discussion on TEM detection of asbestos fibers and regulatory limits referenced.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000437306
Lab report discussing TEM vs optical microscopy and regulatory asbestos limits.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000306672
Discussion on TEM vs optical microscopy for asbestos fiber detection and history.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000450586
PCM asbestos method overview and regulatory limits for fibers.
11 shared non-person entities · 1 shared topics · similarity 0.941
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451078
Asbestos and other fibers by PCM/TEM method 7400; evaluation guidelines included.
11 shared non-person entities · 1 shared topics · similarity 0.941
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434430
PCM/NIOSH/ACGIH reference for asbestos fiber measurement; method 7400 with detection limits.
11 shared non-person entities · 1 shared topics · similarity 0.941
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442815
Fiber analysis method overview and PCM/NIOSH/OSHA references for asbestos.
11 shared non-person entities · 1 shared topics · similarity 0.941
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433590
PCM analysis of asbestos and other fibers with reference thresholds.
11 shared non-person entities · 1 shared topics · similarity 0.941
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000307170
Discussion on TEM detection of asbestos fibers and regulatory limits referenced.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318625
Overview of TEM vs optical microscopy for asbestos fiber measurement and historical context.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000306672
Discussion on TEM vs optical microscopy for asbestos fiber detection and history.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000307170
Discussion on TEM detection of asbestos fibers and regulatory limits referenced.
Similarity score 0.977 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000306672
Discussion on TEM vs optical microscopy for asbestos fiber detection and history.
Similarity score 0.974 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318625
Overview of TEM vs optical microscopy for asbestos fiber measurement and historical context.
Similarity score 0.973 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000307170
Discussion on TEM detection of asbestos fibers and regulatory limits referenced.
Similar indexed content
NYC-WTC_000318625
Overview of TEM vs optical microscopy for asbestos fiber measurement and historical context.
Similar indexed content
NYC-WTC_000437306
Lab report discussing TEM vs optical microscopy and regulatory asbestos limits.
Similar indexed content
NYC-WTC_000306672
Discussion on TEM vs optical microscopy for asbestos fiber detection and history.
Similar indexed content
NYC-WTC_000289570
Glossary and reference material on asbestos terms and regulations used for lab context.
Similar indexed content