NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 6 pages

Asbestos TEM/OSHA discussion, TEM analysis excerpt, 1970s

Machine-extracted title · confidence 28%

Discussion on TEM detection of asbestos fibers and regulatory limits referenced.

NYC-WTC_000307170–000307175
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

f

AAUTDAIIEDCV THE SMALL. FIBER

UUIIIIIUIUIUI By Bruce E. Lippy, Jeffrey A. Boggs, and Christopher A Lambesis

N o one who measures airborne asbestos fibers disputes the fact that the transmission electron microscope (TEM) is able to detect smaller concentrations enforced by regulatory agencies. When the Occupational Safety and Health Administration (OSHA) was created in 1970, it enforced a level of fibers than the optical microscope. How can potentially 12 f/cc. The standard was promulgated in Environmental Protection Agency (EPA) 1972, setting a permissible exposure limit guidebooks point out that TEM routinely dangerous small (PEL) of 5 f/cc with a mandatory decrease resolves fibers of 0.0025 micrometers in to 2 f/cc in 1976. At this time, there were diameter, 100 times more sensitive than asbestos fibers best no criticisms of the optical microscope’s phase conrast microscopy (PCM). The ability to report these levels with statistical TEM method, however, is a great deal be detected? significance. more expensive. The OSHA PEL has continually Cost versus quality analysis is a decreased as concerns about worker safety dilemma that raises many issues including; have increased. In 1983, the court.s nullified the importance of small fibers, does the a short-lived Emergency/Temporary ability to detect them really merit an Standard of 0.5 ficc. However, the current additional expense and does reporting them It was certainly reasonable to assume that PEL of 0.2 f /cc was promulgated for dilute data on longer, reportedly more any fibers taken from a worker’s breathing general industry and construction in 1986. dangerous fibers? These questions can be zone were asbestos. The standards also contain an action level analyzed by evaluating; Similarly, the sensitivity of optical of 0.1 f/cc. This is a decrease of 120 percent 1. the differences between phase microscopy was not being tested as it from the original 12 f/cc level—quite a contrast microscopy (PCM) and TEM in is today since long fibers were valued demand on the sensitivity of any analytical analytical capabilities; commercially. As a result, there was little method. 2. the fiber size distribution - ofasbestos business interest in short fibers and virtually To exacerbate the problem further, reported in the air and in lung tissue; and no scientific interest. Seidman reported that ERA'S Asbestos Hazard Emergency 3. the medical significance of short an average airborne concentration of 23 Response Act (AHERA) regulations require fibers. fibers per cubic centimeter (f/cc) existed in that when optical microscopy is used, the a plant in Tyler, Texas, that manufactured release level is 0.01 f/cc. Indeed, abatement DIFFERENCES IN ANALYTICAL asbestos pipe insulation.' specifications calling for 0.005 f/cc are far CAPABILITIES Unfortunately, exposures of this from rare. This represents a 2,400 percent A historical perspective is essential magnitude were far from rare. NIOSH reduction from the original OSHA level. when discussing the analytical methods reported levels of 14 to 75 f/cc in similar Critical differences between airborne used to measure airborne asbestos. In workplaces. Initially, the main sampling asbestosfibers in workplaces and buildings. 1972, when the National Institute for concern with the optical method was to The new OSHA standards contain a new Occupational Safety and Health (NIOSH) avoid overloading filters with asbestos sampling and analytical procedure called fomiulated the P&CAM 239 optical fibers, not whether enough fibers had been the OSHA Reference Method (ORM).’ microscope method, there was no reason collected or whether they were asbestos. This method is essentially the same as the to be overly concerned with the specificity Additionally, fewer than 12 labs even NIOSH 7400 Method in that it defines of the method itself. At the time, asbestos pursued TEM analysis of asbestos for a fiber as anything with an aspect ratio was used in thousands of products. The research purposes in the early 1970S. of 3-to-l and a length greater than 5 material was shipped in bags that were Another important historical perspective micrometers. The ORM is solid proof that ripped and routinely dumped into hoppers. is the continually decreasing airborne the government does not consider optical

ASBESTOS ISSUES '89—MARCH

CITY_21MC100_0 11963913

NYC-WTC_000307170

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000307170Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Small fiber study: TEM vs OSC

NYC-WTC_000318625

Overview of TEM vs optical microscopy for asbestos fiber measurement and historical context.

Similar indexed content

Compare copies and versions →