G: EPA’s 110 Liberty St. study, Deutsche Bank building - 132

the PCMe test. In addition, wipe samples of smooth surfaces demonstrated that asbestos dusts were higher tlian before EPA did its 1* abatement.

Three air samples, seven micro vacuum samples and four wipe samples were collected for asbestos. The air samples were analyzed for PCM, TEM AHERA, and PCMe. The PCM results indicate that all three samples were below the secondary numeric criterion of 0.01 f/cc. The TEM AHERA results indicate that two of the samples could not be analyzed due to overloading of particulate material. The remaining sample was below the secondary numeric criterion of 0.0022 S/cc. The PCMe results indicate that two of the samples could not be analyzed due to overloading of particulate material. The remaining sample was below the primary clearance criterion of 0.0009 S/cc.

The results of the seven micro vacuum samples indicate that asbestos was present at concentrations lower than those observed before cleaning. The results of the wipe samples indicate that asbestos was present in all four samples at higher concentrations than those observed before cleaning. [EPA calls this the “Post 1^' cleaning Test 4A results’]

Mattress store, results after 2"** failed abatement

For the 2"“* abatement, EPA repeated the HEPA vacuuming with the simultaneous use of an AFD. This time, however, EPA added wet wiping for all walls and horizontal surfaces.

As seen below, the asbestos concentrations by the PCM test were still over 0.01 f/cc PCM. And again, the filters were overloaded with so much particulate that EPA was unable to determine whether the sjimple was over the 0.0009 S/cc PCMe criteria, or even the AHERA TEM level of 70 s/mm\ The asbestos wipe samples also showed that asbestos was present at levels higher than before any abatement.

Three air samples and four wipe samples were collected for asbestos. The three air samples were analyzed using PCM, TEM AHERA, and PCMe. The PCM results indicate that two samples could not be analyzed due to overloading of particulate material and one sample was above the secondary numeric criterion of 0.01 f/cc. The TEM AHERA and PCMe analyses could not be analyzed due to overloading of particulate matter.

Asbestos was present in three of the four wipe samples at higher concentrations than those observed before cleaning

Mattress store, results after 3"* failed abatement

For the 3’^'* abatement, EPA again repeated the HEPA vacuuming, AFD, and wet wiping in the mattress store, as well as wet wiping. However, this time EPA added a hot water wet extraction process with carpet shampoo for the carpet.

NYC-WTC_000251288

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000251288Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →