G: EPA’s 110 Liberty St. study, Deutsche Bank building - 131
Simultaneous abatement of HVAC system necessary, 110 Liberty St. study proves
There was an HVAC system for the stores in the building, but not for the apartments. The mattress stored was rigorously abated three times by EPA, but still failed testing. It was only after the whole central heating and ventilation system (HVAC) was abated that EPA was able to lower asbestos levels in air to meet EPA’s WTC criterion.
Mattress store, before abatement
In the mattress store, prior to any abatements, even though the dust contained less than 1% asbestos, the air levels were higher than 0.01 Fee PCM, which is the light microscope regulatory clearance level under AH ERA."" This level is also the NYC DOH clearance level The NYC DEP had instnicted landlords that there was no problem if the dust itself contained less than 1% asbestos, and that they only needed to test the dust, not the air, since the NYC DEP and EPA had tested the air outside and found it to be safe. See Section E.
This level of 0.01 f/cc PCM is more than 10 times higher than the level EPA set for the cleanup of WTC dusts in buildings (the PCMe level of 0.0009 S/cc). EPA was not able to determine the PCMe level for 'A of the samples, because the filters were overloaded with particulates and could not be read by the analyst.
Four air, seven micro vacuum, and three wipe samples were collected for asbestos. The air samples were analyzed for PCM and PCMe. The PCM results indicate that two of the samples were above and two of the samples were below the secondary numeric criterion of 0.01 f/cc. The PCMe results indicate that two of the samples could not be analyzed due to overloading of particulate material. The remaining two samples were below the detection limit and below the primary clearance criterion of 0.0009 S/cc. All seven of the micro vacuum samples and all three of the wipe samples detected chrysotile.
Mattress store, results after 1^* failed abatement
For the P‘ abatement, a professional quality HEPA vacuum was used for the carpet, walls, and all other surfaces. An air filtration device (AFD) was used at the same time as the HEPA vacuuming. An AFD is a local exhaust system with HEPA filtration that is capable of creating and maintaining a negative pressure differential between the outside and the inside of the work area. The AFD functions as a stand-alone piece of equipment in a room. The AFD was used as an air-polishing device, to capture dust particles that became airborne as a result of disturbances caused by the abatement activities.
The air and surfaces were tested for asbestos after this I” abatement. EPA was unable to determine whether its WTC criteria for air was met, because the filters were overloaded again in
NYC-WTC_000251287
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000243169
Department memo referencing 9/11 toxic hazards at Ground Zero site.
63 shared non-person entities · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145345
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
56 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145510
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
57 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318340
Office findings on EPA response to World Trade Center issues; August 2003.
57 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000148115
Frequently asked questions and updates regarding disaster assistance, road reopenings, and victim support funds issued in October 2001.
44 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125845
Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.
48 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000144723
Official correspondence from the NYC Law Department regarding the collection and preservation of World Trade Center documents for legal use.
18 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000161674
Document excerpt listing counsel and staff members assigned to a paper on infrastructure related to World Trade Center recovery.
22 shared non-person entities · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140235
Memorandum comparing asbestos data in Manhattan to other sites and arguing for cleanup under the Superfund statute.
26 shared non-person entities · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000144741
Standard administrative notice requiring the retention of original World Trade Center records as evidence for future legal actions.
40 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155264
Letter from EPA official to a Congressional representative criticizing the adequacy of the 114 Liberty Street cleanup.
26 shared non-person entities · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000154976
Correspondence criticizing the EPA and DEP regarding asbestos, silica levels, and safety clearance after cleaning at 114 Liberty Street.
26 shared non-person entities · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000318340
Office findings on EPA response to World Trade Center issues; August 2003.
Similarity score 0.958 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145345
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
Similarity score 0.958 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145510
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
Similarity score 0.958 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145695
Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
Similarity score 0.958 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000154976
Correspondence criticizing the EPA and DEP regarding asbestos, silica levels, and safety clearance after cleaning at 114 Liberty Street.
Similarity score 0.957 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155264
Letter from EPA official to a Congressional representative criticizing the adequacy of the 114 Liberty Street cleanup.
Similarity score 0.957 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000243169
Department memo referencing 9/11 toxic hazards at Ground Zero site.
Similar indexed content
NYC-WTC_000145345
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
Similar indexed content
NYC-WTC_000145510
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
Similar indexed content
NYC-WTC_000318340
Office findings on EPA response to World Trade Center issues; August 2003.
Similar indexed content
NYC-WTC_000148115
Frequently asked questions and updates regarding disaster assistance, road reopenings, and victim support funds issued in October 2001.
Similar indexed content