NYC 9/11 Public Portal Document

G: EPA’s 110 Liberty St. study, Deutsche Bank building - 131

Simultaneous abatement of HVAC system necessary, 110 Liberty St. study proves

There was an HVAC system for the stores in the building, but not for the apartments. The mattress stored was rigorously abated three times by EPA, but still failed testing. It was only after the whole central heating and ventilation system (HVAC) was abated that EPA was able to lower asbestos levels in air to meet EPA’s WTC criterion.

Mattress store, before abatement

In the mattress store, prior to any abatements, even though the dust contained less than 1% asbestos, the air levels were higher than 0.01 Fee PCM, which is the light microscope regulatory clearance level under AH ERA."" This level is also the NYC DOH clearance level The NYC DEP had instnicted landlords that there was no problem if the dust itself contained less than 1% asbestos, and that they only needed to test the dust, not the air, since the NYC DEP and EPA had tested the air outside and found it to be safe. See Section E.

This level of 0.01 f/cc PCM is more than 10 times higher than the level EPA set for the cleanup of WTC dusts in buildings (the PCMe level of 0.0009 S/cc). EPA was not able to determine the PCMe level for 'A of the samples, because the filters were overloaded with particulates and could not be read by the analyst.

Four air, seven micro vacuum, and three wipe samples were collected for asbestos. The air samples were analyzed for PCM and PCMe. The PCM results indicate that two of the samples were above and two of the samples were below the secondary numeric criterion of 0.01 f/cc. The PCMe results indicate that two of the samples could not be analyzed due to overloading of particulate material. The remaining two samples were below the detection limit and below the primary clearance criterion of 0.0009 S/cc. All seven of the micro vacuum samples and all three of the wipe samples detected chrysotile.

Mattress store, results after 1^* failed abatement

For the P‘ abatement, a professional quality HEPA vacuum was used for the carpet, walls, and all other surfaces. An air filtration device (AFD) was used at the same time as the HEPA vacuuming. An AFD is a local exhaust system with HEPA filtration that is capable of creating and maintaining a negative pressure differential between the outside and the inside of the work area. The AFD functions as a stand-alone piece of equipment in a room. The AFD was used as an air-polishing device, to capture dust particles that became airborne as a result of disturbances caused by the abatement activities.

The air and surfaces were tested for asbestos after this I” abatement. EPA was unable to determine whether its WTC criteria for air was met, because the filters were overloaded again in

NYC-WTC_000251287

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000251287Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →