NYC Law Department release
Independent mirror · updated as the City releases more · v1.3.2
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 38 pages

NYC-WTC_000232127

Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000232127–000232164
Page image
Scanned page image, NYC-WTC_000232154
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part II - Environmental Community Monitoring Plan 133-135 Greenwich & 21-23 Thames Streets Airtek Project 05-0701 - Rev 2 September 16, 2005

range of temperature and humidity. Before being weighed, both unexposed and exposed filters must be conditioned for at least 24 hours in this environment.

The exposed sample filters are transported in a cooler to limit the loss of volatile material, and are then kept in a refrigerator if they are cannot be weighed within 10 days of sampling (they still must be weighed within 30 days of sampling to be valid). Unexposed filters arc taken out to the site under similar controlled conditions (usually in a cooler, although this is not necessary).

• Data requirements:

o Backup instruments, field staff, and supplies will be maintained throughout the monitoring duration to ensure continuous operation of monitoring stations and high data recovery.

o Data quality objective: 10% coefficient of variation. The coefficient of variation, CV, is the standard deviation as a fraction of the mean: CV =^. JT

• Measures of Accuracy and Bias:

o Check of flow rate

o Audit by collocation with a portable FRM sampler.

Measures of Precision:

o Check of flow rate

o Collocation (see below).

Collocation:

o Monitors have a second monitor collocated at the same site, rotated between sites.

o The second ("duplicate") sampler runs every 6 days.

o Collocated particulate samplers must be less than 4 m apart but more than 1 m apart.

The PM2.5 sampler requires enhanced quality control measures because of its unique design and operational attributes. Examples of these QC measures include:

• Filter equilibration temperature control of +/-2 °C over 24 hours

• A pre-sampling filter weighing within 30 days of sampling period

• Retrieving the filter from the sampler within 96 hours of collection

• A post-sampling filter equilibration and re-weighing within 240 hours after the sampling period

28

CITY_DEP_WORBY_CANNATA_SUBP_000087273

NYC-WTC_000232154

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000232154Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →