NYC Law Department release
Independent mirror · updated as the City releases more · v1.3.2
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos inspection log, 130 Liberty Street, March 20, 2009

Machine-extracted title · confidence 95%

Record of an asbestos inspection conducted at 130 Liberty Street on March 20, 2009, by TRC Environmental Corp.

NYC-WTC_000182023
Page image
Scanned page image, NYC-WTC_000182023
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Asbestos Inspection Report

Premise No. Inspection Date: 130 Liberty Street 03/20/09 Floor Zip Borough Block Lot Squad # Badge # Various_________ 10006 1 54 1 1 AO61 Inspector Building Type Basis of Inspection Photos Taken H. Guirguis A TRU2068MN08 Yes Contractor's Name Sample Number LVI Environmental Address City Sample Number

State Zip Phone Sample Number

Laboratory Name Owner's Name TRC Environmental Corp The Lower Manhattan Development Corp, Address City Address City 1430 Broadway New York One Liberty Plaza New York State Zip Phone State Zip Phone NY 10018 NY 10006 (212) 962-2300 Contact Person Time of Inspection from: Arnel Javal, Sr. Proj. Mgr./TRC Environmental 08:00am - 10:00am

On arrival I met Nugent Gerald, Supervisor for LVI Environmental at the LVI field office, who informed me that a total of 1 Handler Supervisor and 50 Asbestos Handlers were in the 3'“ floor today. The daily work schedule informed me of the following. 1. 3"* floor: 50 men-scrape fireproofing, clear off floor 2. 2'’" floor: 54 men- seal critical, clear off floor. Eagle-14 men erect platforms various locations 3. l” floor: 76 men-clear floor, cut ducts, demo walls, ceilings, etc. 4. Various floors : 14 men loading out boxes to ATC trailer I went to the decontamination enclosure system in the first floor at the west side After signing the log book donned personal protection and accessed the work areas, I used stair B to go to from Y'floor to 3''^ floor. V'& 2"“ floor: workers were found in the process of removing and wrapping debris; there was still a lot of wet debris on the floor, demo walls, demolition was not completed, workers were cutting metal ducts and electrical conduits into small pieces using power tools, HEPA vacuum attached with the power tools, disconnecting Mechanical Equipment (HVAC), fine spraying amended water in the work area, preparing Gaylord boxes, wrapping beams and lighting fixtures. Inspecting the critical barriers and re-sealing with duct tape, erecting scaffolds and platforms in various locations, numerous Gaylord boxes and poly wrapped beams were at various locations on each floor ready to be taken out Inspection was done on the Micro trap Machines and the Micro trap tents and on all the work area. 3'“ floor, workers were found in the process of scraping and boxing fireproofing, fine spraying amended water in the work area, preparing Gaylord boxes. Inspection was done on the Micro trap Machines and the Micro trap tents and on all the work area. I exited the work area after decontaminating and signing the log book.

NOV# Infraction Infraction Infraction Infraction

NOV# Infraction Infraction Infraction Result Code 2 NOV# Infraction Infraction Infraction Supervisor|^s^ial

Borough l=Manhattan 2=Bronx 3=Brooklyn 4=Queens 5=Richmond Building Type A >6 stories B <6 stories C single family D school E hospital F public owned Result Code I = Violation Issued 2=No Violation Issued 3=No access 4=Project not started (no NOV) 5=Public Owned Property

C ITY_D EP_WO RBY_C AN NAT A SU B POO0131172

NYC-WTC_000182023

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000182023Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →