NYC 9/11 Public Portal Document
Asbestos Inspection Report
Premise No. Inspection Date:
130 Liberty Street 05/27/09
Floor Zip Borough Block Lot Squad # Badge #
I^Fl__________ 10006 1 54 1 1 A062
Inspector J”Buiiding7v^ Basis of Inspection Photos Taken
M.Gagnidze TRU2068MN08 yes
Contractor's Name Sample Number
LVI Environmental Services Ino
Address City Sample Number
462 Gerry Ave Clifton________
State Zip Phone Sample Number
NJ 07011 (973) 772-3660
Third Party Air Monitor Owner’s Name
TRC Environmental Corp The Lower Manhattan Development Corp.
Address City Address City
1340 Rrnadway New York One Liberty Plaza New York
State Zip Phone State Zip Phone
NY 10018 (212)221-7822 NY 10006 (212) 962-2300
Contact Person Time of Inspection from:
Arnel Javal, Sr. Proj. Mgr/TRC Environmental 6:10 pm to 7:00 pm
I entered the premise at 6:10 pm. LVI schedule informed that activities include:
Clear floor, scrape fireproofing, load out on r' floor.
I proceeded to the decon, signed the log book, don the appropriate level of personal
protective equipment to enter the regulated area on Tfloor. Three workers were present
for the decon maintenance, cleaning the shower chambers and organizing the clean room.
Negative air pressure was -0.038.
V Floor - 51 Asbestos Handlers were found inside the work area in the process of:
scraping fireproofing, spraying with water, cleaning the floor, picking up debris, placing
into the boxes at the area 4 - north/east side of work area. Workers on scissor lift were scraping
fireproofing at the east side hallway.
At the north/west side corner two workers on scaffolds were cutting and removing metal
panels from the column using equipment equipped with HEPA filters, spraying the area with
amended water. At the former computer room workers preparing the area for fireproofing removal,
moving scaffolds and resealing the critical barriers with poly, clearing the floor, covering
electrical panel with poly.
Workers at the north side waste decon were cleaning the floor using wet-dry shop HEPA vacuum.
Others were cutting metal into the pieces at the west side vestibule near former mechanical room,
placing into the boxes and spraying; preparing, wrapping and loading out sealed and sprayed
boxes through the north side waste decon.
12Gaylord boxes were ready for load out. 35 micro trap machines were powered on and
5 on stand by. Inspection was done on micro trap tents.
After following the decontamination procedure I signed the log book and left the decon.
Inspection was done on ATC trailer.
NOV# Infraction Infraction Infraction Infraction
NOV# Infraction Infraction Infraction Result Code
2
NOV# Infraction Infraction Infraction Supervisor's Initial
Borough l=Manhartan 2=Bronx 3=Brooklyn 4-Queeris 5=Rjchmond
Building Type A >6 stories B <6 stories C single family D school E hospital F public owned