Client Name; TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; New York City Law Department; 100 Church Street
Flow Air Fiber Fibers
SciLab Client Dale Rate Duration Filtered Density Cone. TWA
Fields Fibers
Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/ce)
01 GS-2/23/02-STEL-0618 2/23/02 2 30 60 too 2 2.55 , < 0,045
Loading Dock. East Side
02 GS-2/23/02-STEL-0619 2/23/02 2 30 60 100 1.5 1.91 < 0.045
Loading Dock, West Side
03 GS-2/23/02-STEL-0620 2/23/02 0 0 0 100 0.5 0.64
Blank Footnotes: /
04 GS-2/23/02-STEL-0621 2/23/02 0 0 0 100 0.5 0.64
Blank Footnotes: I
Reporting Notes:
(1) Fibers/cc cannot be calculate with no air volume.
Analyzed by: Tatyana Grimchak y ; Date Analyzed; 2/23/02
Samples analyzed by NIOSH 7400(A) Met 8/15/94; Limit of Detection® 5.5 fibers per 100 fields or 7 fibers/mm2; This report relates ONLY to the sample analysis expressed as fibeis/sq mm of filter area: ND=No fibers observed: NA=Not
Analyzed; Walton-Beckett graticle field area = 0.00783 mni2: TWA » 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled; Upper 93% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with (he 0.01 fibcr/cc standard: Estimated relative standard deviation: Intralab Sr=0.403, Interlab St=0.43, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102843.
O
----- L
o
o
o
I
o
4^
cn
co
o
o
00
NYC-WTC_000174429
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000174429Source: NYC Law Department, mirrored locally