SciLab Job #: 201092964 Page 3 of 3
Client Name: GCI Environmental Advisory, Inc.
Phase Contrast Microscopy (PCM) Fiber Results
N01-B4087; Rockrose Development Corp.; 333 Rector Place
Flow Air Fiber Fibers
SciLab Client Date Rate Duration Filtered Density 2 Conc.
Fields Fibers TWA
Sample # Sample # / Location Collected ( liters/min.) (min.) (liters) (Fibers/mm ) (Fibers/cc)
31 333-PH-9/24-31 9/24/01 15 60 900 100 13 16.56 0.007
Apt.! Kitchen (CAS)
32 PII 333-PH-9/24-32 9/24/01 15 60 900 100 7 8.92 0.004
Apt.; Kitchen (CAS)
Reporting Notes:
(1) fibers/cc cannot be ca iu ed I' same es ,( r blanks) with no air volume.
Analyzed by: Anthony Hinton _{ •{_"~ __ Date Analyzed: 9/2 5/01
Samples analyzed by NIOSI17400(A) Method. Issue #2, 8115/94; Limit of Dectection= 5.5 fibers per 100 fields or 7 ftbers/n in2; This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area; ND= no fibers observed; NA = not
analyzed; Walton-neckett gradicule field area 0.00785 mm2; TWA =8 l Ir TWA calculation assunx:s zero exposure for remainder of 8 hr period not sampled; Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with die 0.01 fiber/cc standard; Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOU ELAP Lab It 11480); National Institute cf Standards and Technology
I
NYC-WTC 000120611
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000120611Source: NYC Law Department, mirrored locally