NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 48/22 RIVER TERRACE Block: 16 Lot: 190 BIN: 1085929 Park Place, Warren Street
Document / 49 pages

Air quality analysis report, 22 River Terrace, Sep 2001

Machine-extracted title · confidence 95%

Laboratory report on ambient air samples collected at 22 River Terrace indicating levels below recommended asbestos criteria.

NYC-WTC_000120885–000120933

Folder label: “22 RIVER TERRACE Block: 16 Lot: 190 BIN: 1085929 Park Place, Warren Street

Page image
Scanned page image, NYC-WTC_000120887
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

SciLab Job #: 201092731 Page 2 of , 2 Client Name: GCI Environmental Advisory, Inc. Phase Contrast Microscopy (PCM) Fiber Results NO1-B4086; Rockrose Development Corp.; 22 River Terrace, NYC! CLEARANCE Flow Air Fiber Fibers SciLab Client Date Rate Duration Filtered Fields Fibers Density Conc. TWA Sample # Sample #1 Location Collected ( liters/min.) (min.) 2 (liters) (Fibers/mm ) (Fibers/cc)

16 9/21-16 9/21/01 15 60 900 100 5 6.37 <0.003 Apt.l Loom /CAS 17 -9/21-17 9121/01 15 60 900 100 3,5 4.46 < 0.003 Apt.; /CAS 18 -9121-18 9/21/01 15 60 900 100 2 2.55 < 0.003 Apt.; fCAS 19 ;9/21-19 9121/01 15 60 900 100 3 3.82 < 0.003 AptJ om /CAS 20 19/21-20 9/21/01 15 60 900 100 3 3.82 < 0.003 Apt; ;CAS 21 ;9/21-21 9/21/01 15 60 900 100 2 2.55 < 0-003 Apt tom /CAS 22 'r 9/21-22 9/21/01 15 60 900 100 3 3.82 < 0.003 Apt -.-.-.--.-.-.--.-.-.--.-.-.-, ACAS Reporting Notes: ( I i I ihrt s/cc cannot h r;/c 1t sampics for blanks) with no a;r volume. As c ce,t I". ;ana (irs sschak / Date Analyzed: 9/22/01

Sans; ks .sns/ zed by lOSI 1710!1(.'1! Method, Issue 92, 8/15194; Limit of Deetection= 5.5 fibers per 100 fields or 7 fibershnm2; This report relates ONLY to the sample analysis expressed as fibers/sq nun of filter area; ND = no fibers observed; NA = not an Ivied; 'Aalton-lteckctt gradicule f ehi area 0.00785 mm!; TWA =8 fir TWA calculation assumes zero exposure for remainder of 8 hr period not sampled; Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to determine 95% certainty of compliance with the 0.01 fiber/cc standard; Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOII FLAP Lab # 11480); National Institute of Standards and Technology

NYC-WTC 000120887

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000120887Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →