Samples analyzed by NIOS1l 7400(A) Method, Issue #2, 8/15/94; Limit of Dectection= 5.5 fibers per 100 fields or 7 fibers/mm2; This report relates ONLY to the sample analysis expressed as fibers/sq mm of fi lter area; ND = no fibers observed; NA = not
analyzed; Walton-Beckett gradicule field area 0.00785 mm2; TWA =8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled; Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0.01 fiber/cc standard; Estimated relative standard deviation: Intrrlab Sro0.405, Interlab Sr=0.45, New York samples (NYSDOIt ELAP Lab # 11480); National Institute of Standards and Technology
N
NYC-WTC 000120616
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000120616Source: NYC Law Department, mirrored locally