Air quality analysis report, 22 River Terrace, Sep 2001

Machine-extracted title · confidence 95%

Laboratory report on ambient air samples collected at 22 River Terrace indicating levels below recommended asbestos criteria.

NYC-WTC_000120885–000120933

Folder label: “22 RIVER TERRACE Block: 16 Lot: 190 BIN: 1085929 Park Place, Warren Street

Page image
Scanned page image, NYC-WTC_000120914
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

SciLab Job #: 201092829 Page 4 of 4 Client Name: GCI Environmental Advisory, Inc. Phase Contrast Microscopy (PCM) Fiber Results NOI-B-4086; Rockrose Development Corp.; 22 River Terrace, New York, NY Flow Air Fiber Fibers SciLab Client Date Rate Duration Filtered Density Cone. Fields Fibers TWA Sample # Sample 4/Location Collected ( liters/min.) (min.} {liters) (Fibers/mm 2 ) (Fibers/cc)

46 22-9/23-46 9/23/2001 15 65 975 100 7 8.92 0.004 'Room: Kitchen I CAS 47 22-9/23-47 9/23/2001 15 65 975 100 14 17.83 0.007 Room: Kitchen! CAS 48 22-9/23-48 9/23/2001 15 65 975 100 5 6.37 <0.003 P11 doom: Kitchen / CAS 49 22-9/23-49 9/23/2001 15 65 975 100 8 10.19 0.004 ;Room: Kitchen / CAS 50 22- 9/23- 50 9/23/2001 15 64 960 100 4 5.10 < 0.003 Room: Kitchen / CAS Reporting Notes: (1) Fibers/cc cannot he calculalst for samples (or blanks) with no air volume. Analyzed by: Victor Slopac _-- Date Analyzed: 923/-001 ~

Samples analyzed by NIOSII 7400(A) Method, Issue #2, 8/15/94; Limit ofDectection= 5.5 fibers per 100 fi elds or 7 fibers/mm2; This report relates ONLY to the sample analysis expressed as fibers/sq mm of fi lter area; ND = no fibers observed; NA = not analyzed: Walton-Beckett sradicule field area 0.00785 mm2: TWA =8 Fir TWA calculation assumes zero exposure for remainder of 8 hr period not sampled; Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to determine 95`x+ certainty 01 compliance with the 0.01 fiber/ce standard; Estimated relative standard deviation: lntralah Sr=0.405, Inter lab Sr=0.45, New York samples INYSDOI I FLAP Lab # 11480); National Institute of Standards and Technology

NYC-WTC 000120914

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000120914Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →