SciLab Job #: 201092965 Page 4 of 4
Client Name: GCI Environmental Advisory, Inc.
Phase Contrast Microscopy (PCM) Fiber Results
N01-B4087; Rockrose Development Corp.; 333 Rector Place
Flow Air Fiber Fibers
SciLab Client Date Rate Duration Filtered Density Conc.
Fields Fibers TWA
Sample # Sample # / Location Collected ( liters/min.) (min.) (liters) (Fibers/mm 2 ) (Fibers/cc)
44 333-9124-44 9/24/2001 15 68 1020 100 2 2.55 < 0.003
Apt Kitchen (CAS)
45 P11 333-9124-45 9/24/2001 15 68 1020 100 3 3.82 < 0.003
Apt; ;Kitchen (CAS)
Reporting Notes:
(1) Fibers/cc cannot be calctil 'ed f s pies (or la witivno air volume.
Analyzed by: Tatvana Grimchak ✓. Date Analyzed: 9252001
Samples analyzed by NIOSH 7400(A) Method. Issue #2, 8!15/94; Limit of Deciection= 5.5 fibers per 100 fields or 7 fibers/mm2; This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area; ND = no fibers observed; NA = not
analyzed; Walton-Ileckett gradicule field area 0.00785 mm2; TWA =8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled; Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0.01 fiber/cc standard; Estimated relative standard deviation: intralab Sr=0.405, Interlab Sr ).45, New York samples (NYSDOH ELAP Lab # 11480); National Institute of Standards and Technology