PPS-Generators

C. ANSI/NEMA 250 - Enclosures for Electrical Equipment.

D. ANSI/IEEE 446 - Emergency and Standby Power Systems.

E. NYC Electrical Code

2.04 QUALITY ASSURANCE

A. In order to define requirements for quality and function, product specifications designate manufacturers.

2.05 SUBMITTALS

A. Submit product data.

B. Submit short circuit and coordination smdy.

C. Submit product data, list of materials, service location.

D. Submit alternate price quotations.

2.06 EMERGENCY ELECTRIC GENERATING SETS

A. Emergency electric generating sets shall be automatic starting diesel single engine driven, shall have nominal electric characteristics of 480/277 volts, 3 phase, 4 wire, 60 cycles and shall each be able to supply its indicated load at power factors down to 80%. The sets shall be suitable for operation, in conjunction with the generator control switchgear as an automatically started and paralleled plant.

B. The emergency generator sets and all their associated controls and appurtenances shall be suitable for use where the load to be supplied consists of non-linear loads such as solid sute transistorized or SCR drives or UPS systems supplying computers and variable speed motor drives. Submit manufacturer's certification thereto.

C. Submit manufiicturers certification that, with supply facilities provided and ambient conditions maintained as hereinafter specified, the engine generator sets, in conjunction with the generator control switchgear, are capable of meeting the following performance criteria:-

OEM PPS-9 Generators 7 WTC March 20, 1998

NYC-WTC_000166884

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000166884Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Electrical proposal, ADCO Electrical Corp., May 1998 · Box 7DCAS

NYC-WTC_000172686

Revised electrical work proposal from ADCO Electrical Corporation for the Mayor's Office of Emergency Management on the 26th floor at 7 World Trade Center in May 1998.

2 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.881

machine-extracted · confidence unavailable · Check page ↗
HVAC specification supplement, unknown date · Box 7DCAS

NYC-WTC_000173223

Supplement to HVAC specifications detailing discharge plenum construction standards for emergency generators at the Mayor's Office of Emergency Management.

1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.879

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →