← Document results/7DCAS/GENERATOR PREPURCHASE SPECIFICATION
Document / 52 pages

Transmittal of generator prepurchase specifications, March 1998

Machine-extracted title · confidence 90%

Cover sheet transmitting requested prepurchase specifications for generators to the Department of Citywide Administrative Services.

NYC-WTC_000166874–000166925

Folder label: “GENERATOR PREPURCHASE SPECIFICATION

Page image
Scanned page image, NYC-WTC_000166883
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

PPS-Generators

2. Lubrication Schedule: Indicating type and frequency of lubrication required.

3. List of Spare Parts: Recommended for normal service requirements.

4. Parts f -ist: Identifying the various parts of the equipment for repair and replacement purposes.

5. Instruction Books may be standard booklets but shall be clearly marked to indicate applicable equipment.

6. Wiring Diagrams: Generalized diagrams are not acceptable, submittal shall be specifically prepared for this Project.

7. Automatic Controls: Diagrams and fimctional descriptions.

C. Where applicable, one set of operating and maintenance instructions shall be neatly framed behind glass and himg adjacent to the equipment concerned.

PART 2 - PRODUCTS

2.01 WORK INCLUDED

A. Emergency Generator Sets.

B. Radiator mounted load banks, control panels.

C. Generator power and control switchgear.

D. Automatic transfer switches.

2.02 RELATED WORK

A. Section 15000 - Fuel Oil Tank and Piping

B. Section 15000 - Acoustical Treatment, Dampers, Operators.

2.03 REFERENCES

A. ANSI/NFPA 70 - National Electrical Code

B. ANSI/NEMA MG-1 - Motors and Generators.

OEM PPS-8 Generators 7 WTC March 20, 1998

NYC-WTC_000166883

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000166883Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Electrical proposal, ADCO Electrical Corp., May 1998 · Box 7DCAS

NYC-WTC_000172686

Revised electrical work proposal from ADCO Electrical Corporation for the Mayor's Office of Emergency Management on the 26th floor at 7 World Trade Center in May 1998.

2 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.881

machine-extracted · confidence unavailable · Check page ↗
HVAC specification supplement, unknown date · Box 7DCAS

NYC-WTC_000173223

Supplement to HVAC specifications detailing discharge plenum construction standards for emergency generators at the Mayor's Office of Emergency Management.

1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.879

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →