CD80AF3 and CD80AF4 PERFORMANCE DATA

PRESSURE LIMITATIONS

CD80AF3 60" Pressure limitations shown on charts S.^ 48" at left allow maximum blade deflec­ tion of 1/180 of span on 60" damper §1 widths. Deflections in other damper widths (less than 48") at higher pres­ □ .2 sures shown will result in blade de­ E o flection substantially less than 1/180 24" of span. <Q (A s 12" 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Pressure Differential* (Inches Water Gage)

The CD80AF3 may be used in systems with total pressure exceeding 13" w.g. by reducing the damper section width as indicated in the chart. A maximum design total pressure of 17" w.g. would require a CD80AF3 damper with maximum section width of 36".

CO80AF4 60"

) S.x:48" *NOTE:Damper should be specified for a2 fan shut off pressure. Pressure differen­ tial is not system pressure, but is the 3.2 maximum pressure the damper will .§ o encounter with blades closed. iS524'- S 12" 18 20 22 24 26 28 30 32 34 36 38 40 42 44 Pressure Differential* (Inches Water Gage)

The CD80AF3 may be used in systems with total pressure exceeding 20" w.g. by reducing the damper section width as indicated in the chart. A maximum design total pressure of 26” w.g., tor example, would require a CD80AF3 damper with maximum section width of 48".

The CD80AF dampers may tolerate higher pressure limitations than those shown here. Conservative ratings are presented intentionally in an effort to avoid misapplication. Consult Ruskin or your Ruskin representative when a damper is to be applied in conditions exceeding recommended maximums.

I

1

» NYC-WTC_000166824

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000166824Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

HVAC specification supplement, unknown date · Box 7DCAS

NYC-WTC_000173223

Supplement to HVAC specifications detailing discharge plenum construction standards for emergency generators at the Mayor's Office of Emergency Management.

1 shared topics · Same agency, volume and box · similarity 0.902

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →