NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/7DCAS/Pre-Engineered Blast Doors
Document / 17 pages

Pre-hung door specification sheet with dimensions and ratings

Machine-extracted title · confidence 95%

Specification sheet detailing dimensions, pressure ratings, and UL classifications for pre-hung double leaf doors.

NYC-WTC_000166810–000166826

Folder label: “Pre-Engineered Blast Doors

Page image
Scanned page image, NYC-WTC_000166825
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

PRESSURE DROP AREA FACTOR TABLE DETERMINING PRESSURE DROP 6.55 4.37 3.28 2.62 2.18 1.87 1.64 1.46 Use the Area Factor Table and 6.65 4.43 3.33 2.66 2.22 1.90 1.66 1.48 3.89 2.60 1.95 1.56 1.30 1.11 g g II JI Ml M? M? MJ Pressure Drop Chart to determine II .11 :1? .11 S .11 .11 :S .11 :ll .11 .5? 3.93 2.62 1.96 1.57 1.31 1.12 pressure drop through Ruskin CD82AF3/CD82AF4 control damp­ 1:11 Ml Ml g II 5? 11 3 ;ll 1709 79? 1.10 .81 .68 g 1 J? 1 ers. 1. Determine area factor for II Ml Ml II 11 .11 ;I1 g .82 .66 :11 .i g g g 1? damper by entering the Area Ml Ml 1? 769 .69 g :ll II 2 g JI B g g II :ll JI Factor Table through duct width and height. Ml g II .51 g g II g g :1^ JI JI JI JI JI g JI 2. Find the conversion velocity .38 g Ji JI .39 .11 :ll .11 JI JI :ll JI :ll JI g J] J? JI (CV) by multiplying the selected size damper’s area factor by .32 g g :ll .32 g 11 g JI JI Ji :ll JI JI J8 g g g II g ;I1 .27 .27 g g JI JI .JI .JI J? .J? JI .11 S II II II 11 I the flow rate in CFM; CV = Area Factor x CFM. 3. Enter the Pressure Drop Chart :ll [I ;ll .24 .24 g JI JI JI JI JI ;ll I :ll 5? :I1 11 II g J at the determined area factor and proceed up to appropriate g :ll g .21.19 g JI JI JI Ji JI II s 11 5? g g :ll .11 .21 conversion velocity (CV) line. Then, read across to static g g g .17 .19 ;ll JI JI JI -.11 Jl g S :ll II II II JI JI aa :11 g .17 g .15 :tl JI JI :g :ll 11 11 1 :ll II II II 11 .16 JI J] JI g g .:ll .H 51 :ll .11 .11 :g 11 pressure drop at left side of chart.

;ll JI .14 JI JI g 11 IT g K S' II 11 11 11 11 .14

.13 JI II g g 1 II g 11 .11 g :ll g JI .13 11 11 II II g -.11 JI .11.12 :t5 11 •.n g II g [i 11 g 11 II II II .12 & g g JI .12 g :ll 11 g g II :ll 11 11 11 5: II II :ll II Example: Find the pressure drop across an 18" wide x 18" high Model CD80AF4 control damper handling 8570 CFM. From the Area Factor Table, area factor is determined to be .58. CFM X AREA FACTOR EQUALS CONVERSION VELOCITY Therefore, CV (Conversion Velocity) = 8570 CFM x .58 = 5000. Using the pressure Drop Chart, pressure drop = .20 inches water gage.

CD80AF PRESSURE DROP CHART 10 .90 .SO 70 .80 .50 <0 o .40

o .30

IM .20 • O x: o .10 lU .09 .08 fiC .07 3 06 W w 06 UJ 04 fiC Q. 03 2 »- 02

«

01 .02 04 05 06 06 3 4 5 6 20 30 8 10 07 09 7 9

NOTE: AREA FACTOR 1. Ratings are based on AMCA Standard 500 using Test Setup Apparatus Figure 5.3 (damper is installed with duct upstream and down­ stream). 2. Static Pressure and Conversion Velocities are corrected to .075 Ib./cu. ft. air density.

NYC-WTC_000166825

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000166825Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

HVAC specification supplement, unknown date · Box 7DCAS

NYC-WTC_000173223

Supplement to HVAC specifications detailing discharge plenum construction standards for emergency generators at the Mayor's Office of Emergency Management.

1 shared topics · Same agency, volume and box · similarity 0.902

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →