Nobember 10, 1983
City of New York 7
D&partment of Environmental Protecti-on
Division of Sewer Regulation & Control
Bureau of Sewers 4-^
2358 Municipal Building
New York, NY 10007
Attention: Mr. Frederick Novotny, P.E. <
Chief Division of Sewer Regulation and Control
Reference: Amtrak North Access Connection
Tenth Avenue Tunnel
Borough of Manhattan
Subject: Sewer Work in 10th Avenue (95% Submission)
SSV&K No.: 22-6018
Enclosed please find (3) sets of plans revised in accordance with your comnents
as set forth in your letter of October 13, 1983 to Mr. Harry Kamamis, P.E.,
Director, Mass Transit Coordination, N.Y.C.D.O.T.
In answer to Comment No. 12, the proposed 30" R.C.P. which replaces the existing
4'-0" X 2'-8" egg shaped brick sewer, carries the same flow as the 30" R.C.P.
upstream which was installed under M.T.A. Contract No. 1-02-21064-0-0. An
existing 6" C.I.P. force main and an existing 24" C.I.P. force main which tie
into the existing 4'-0" x 2'-8" egg shaped brick sewer are being relocated (see
Dwgs. C-UTl and CUT2.). The relocated force mains and the manhole (Manhole #2)
to which they connect will be owned and maintained by Amtrak. No other house
connections to the existing 4'-0" x 2'-8" egg shaped brick sewer to be replaced
are known to exist.
I have enclosed computations prepared during the design of M.T.A. Contract No.
1-02-21064-0-0 which indicate that the flow in the sewer rerouted under that
contract is 12.96 C.F.S.. As no additional flow is added to our proposed 30"
R.C.P. it will definitely be adequate to carry this flow (I have also enclosed
computations of the capacity of the proposed 30" R.C.P.). As the existing 6"
C.M.P. and 24" C.M.P. force mains are merely rerouted and then reconnected to
the City System, there will be no additional flow to any portion of the City
STV ENGINEERS. Engineers, Architects. Planners, Construction Managers. Professional Member Firms:
Si V / Bai’smcre Pransportation AsJ5oc!ares; STV'Lyon Associates: STV/Management Consui'ants Group: STV/
ii D. Noitingnarn & Associates' STV/Sanders Of Thomas; STV/Santafnc; STV 'Seelye Stevenson Va’ue & Knecht.
NYC-WTC_000165833
OCR can misread numbers and units. Confirm readings against the page image before using them.