NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 26/No folder label
Document / 21 pages

Ambient dust sampling protocol for residential areas, Oct 2001

Machine-extracted title · confidence 95%

Draft protocol outlining objectives and locations for assessing airborne and settled dust exposures in residential areas.

NYC-WTC_000153220–000153240
Page image
Scanned page image, NYC-WTC_000153225
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

.s

**'^*DRAFT Version 10, October 29, 2001****

particles will be conducted using the lOM™ sampler. The relative amounts (percent weight) of each fraction present will be determined. Each fraction will be analyzed for silica, gypsum, mica, fiberglass, and calcite using X-ray diffraction (XRD) analysis.

Indoor floor dust samples will be collected using the EPA ERT SOP for household dust collection. As much dust as possible wi". be collected; the area vacuumed will be measured and reported. Samples will be analyzed for crystalline silica, gypsum, mica, fiberglass and calcite using XRD. Asbestos will be analyzed using NIOSH Method 9002 (PLM); if <1% is found, TEM analysis will be coi. ducted. The pH of the dust will be tested using EPA SW846 Method 9045C.

2. Outdoor

Outdoor air and settled dust sampling will occur in areas adjacent to the residential building being tested indoors. Sampling will occur concurrently with indoor sampling.

Ambient air sampling will be conducted at breathing height. Air sampling for asbestos will be conducted and analyzed using NIOSH method 7400. If an action level is exceeded subsequent filter analysis using NIOSH 7402 to determine the amount of asbestos fibers present will be - conducted. Respirable crystalline silica will be sampled and analyzed using NIOSH method 7500. Air sampling for inhalable, thoracic, and respirable size particles will be conducted using the lOM^^’ sampler. The relative amoimts (percent weight) of each fraction present will be determined. Each fraction will be analyzed for silica, gypsum, mica, fiberglass, and calcite using X-ray diffraction (XRD) analysis.

ON HOLD? Twelve-hour, continuous, real-time TSP, PMIO and PM 2.5 sampling will be conducted-again at breathing zone height.

Settled surface dust samples will be collected by scraping visible dust into a glass container. A minimum of 25-30 grams of sample is required. Samples will be analyzed for crystalline silica, gypsum, mica, fiberglass and calcite using XRD, and for asbestos using NIOSH Method 9002 (PLM). If PLM shows less than <1%, analyze for asbestos using TEM. The pH of the dust will be tested using EPA SW846 Method 9045C.

Page 6 of

NYC-WTC_000153225

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000153225Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000153258 · Box DEP Box 26

Draft protocol for assessing airborne and settled dust exposures in residential areas following the World Trade Center collapse.

Similar indexed content

Compare copies and versions →