fibers present are asbestos will be conducted. Respirable crystalline silica will be sampled and
analyzed using NIOSH method 7500. Air sampling for inhalable, thoracic, and respirable size
particles will be conducted using the lOM™ sampler. The relative amounts (percent weight) of
each fraction present will be determined. Each fraction will be analyzed for silica, gypsum, mica,
fiberglass, and calcite using X-ray diffraction (XRD) analysis, and for asbestos using PLM
analysis (and TEM analysis if PLM indicates < I %).
Indoor floor dust samples will be collected using EPA ERT SOP for household dust collection.
As much dust as possible will be collected; the area vacuumed will be measured and reported.
Samples will be analyzed for crystalline silica, gypsum, mica, fiberglass and calcite using XRD.
Asbestos will be analyzyed using PLM; if <1% if found, TEM analysis will be conducted. The
pH of the dust will be tested using EPA SW846 Method 9045C.
2. Exterior
Outdoor air and settled dust sampling will occur in areas adjacent to the residential building
being tested indoors. Sampling will occur concurrently with indoor sampling.
Ambient air sampling will be conducted at breathing height. Air sampling for asbestos will be
conducted and analyzed using NIOSH method 7400. If an action level is exceeded subsequent
filter analysis using NIOSH 7402 to determine the amount of asbestos fibers present will be
conducted. Respirable crystalline silica will be sampled and analyzed using NIOSH method
7500. Air sampling for inhalable, thoracic, and respirable size particles will be conducted using
the lOM^*^ sampler. The relative amounts (percent weight) of each fraction present will be
determined. Each fraction will be analyzed for silica, gypsum, mica, fiberglass, and calcite using
X-ray diffraction (XRD) analysis, and for asbestos using PLM analysis (and TEM analysis if
PLM indicates <1%). Twelve-hour, continuous, real-time TSP, PM 10 and PM 2.5 sampling will
be conducted-again at breathing zone height.
Settled surface dust samples will be collected by scraping visible dust into a glass container. A
minimum of 25-30 grams of sample is required. Samples will be analyzed for crystalline silica,
gypsum, mica, fiberglass and calcite using XRD, and for asbestos using PLM analysis (and TEM
analysis if PLM indicates <1%). The pH of the dust will be tested using EPA SW846 Method
9045C.