o o
co
§
c
o
o ***WRAFT Version 10, October 29, 2001****
■D
c
o'
cn "0
o o
ro
KJ
Sample/Analytical Methods
C3> 9L
O
Parameter Environmental.Media Sampling/Analytical Method Sample Flow/time Analytical LOP / LOQ* o
o
c
3
Asbestos*’ VO*” air NIOSH 7400, NIOSH 7402 16L/min-4hr(3840L) 0.010 Vcc (LOQ) CD
3
Breathing zone sample height 5 hr (4800L) 0.008 Vcc
6hr(5760L) 0.007 Vcc
Total Suspended O air EPA Method # (continuous realtime) 12-hr
Particulates Breathing zone sample height
ON HOLD?
PMlOand PM2.5 O air EPA Method # (continuous real-time) 12-hr
ON HOLD? Breathing zone sample height
Inhalable (< 100pm) I/O air lOM personal sampler. Analyze each 2 L/min -5 hr (600L) 30 ug / 50 ug/m’
thoracic (<10pm) fraction for crystalline silica, gypsum,
respirable (<2.5pm) fiberglass, and calcite (XRD)
Respirable VO air NIOSH 7500 2.5 L/min-5.3 hr(800L) 5 ug / 6 ug/m’
crystalline silica
pH I/O dust EPA SW 846 Mtd 9045C (soils) 10-25 g
asbestos I/O dust NIOSH 9002 (PLM), and if (4
LOD:Limit of analytical detection; LOQ: Limit of analytical quantitation
“ use professional judgement re: asbestos sampling times to avoid filter overload (collection of 2 samples with different sampling times
may be necessary)
I: indoor; O: outdoor