NYC 9/11 Public Portal Document
|wlc residential plan octlS.wpd Pages-)
IV. Sampling Parameters:
Parameter Sample Type Indoor/Outdoor Rationale for Selection
Asbestos breathing ht., I/O knoivn u.se in building construction, evidence of IJ
time-weighted presence in early air sampling and in settled dust,
air known inhalation carcinogen 5
Total Suspended breathing ht.. o Characterize amount of airborne dust that is
particulates Continuous, real inhalable (<100 (im aerodynamic diameter)
time, air
PMlOand PM2.5 breathing ht..
Continuous, real
time, air
O Characterize the amount of airborne dust that is
respirable I
I
Inhalable (<100p.m)’ breathing ht., I/O To determine relative amounts of each fraction present
thoracic (<10(im)' time-weighted, and to have each fraction analyzed for silica, gypsum,
respirable (<4pni)’ air asbestos, mica, fiberglass, and calcite to qualitatively
detcnnine potential hazards.
Respirable breathing ht., I/O Known component of concrete, evidence of
crystalline silica time-weighted, presence in some settled dust samples, known
air inhalation carcinogen.
pH" dust I/O Concrete has a high pH, if dust has a high pH, it may be
contributing to reported symptoms of ENT irritation
Asbestos” dust I/O Determine if asbestos is present in dust
g^sum,silica, mica, dust I/O Associated with building materials (concrete,
fiberglass, calcite” drywall) and known to be irritating to ENT
magnesium dust I/O May act as a tracer for WTC-related dust, levels found in
metals analysis of settled dust Irom 16,000-29,000 ppm
■ results will be used to better understand the potential for ENT and respiratory irritation, and possibly for determining the possibility of acute/chronic health