NYCDOH/ATSDR asbestos residential sampling results, Apr 2002

Machine-extracted title · confidence 100%

Transmission of revised asbestos sampling results for residential samples collected November-December 2001.

NYC-WTC_000164784–000164829
Page image
Scanned page image, NYC-WTC_000164789
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

IV. Sampling Parameters

Parameter Sample Type Indoor/Outdoor Rationale for Selection

Asbestos breathing ht., I/O Known use in building construction, evidence of time-weighted presence in early air sampling and in settled dust, air known inhalation carcinogen

Inhalable (<100* m)* breathing ht., I/O To determine relative amounts of each air fraction present thoracic (<10* m)* time-weighted, and to have each fraction analyzed for silica, gypsum, respirable (<4* m)* air mica, fiberglass, and calcite to qualitatively respirable (<2.5* m) determine potential hazards

Respirable breathing ht., I/O Known component of concrete, evidence of crystalline silica time-weighted, presence in some settled dust samples, known air inhalation carcinogen.

pH’* dust I/O Concrete has a high pH, if dust has a high pH, it may be contributing to reported symptoms of eyes, nose, and throat (ENT) irritation

Asbestos” dust I/O Determine if asbestos is present in dust

gypsum, silica, mma, dust I/O Associated with building materials (concrete, fiberglass, calcite” drywall) and known to be irritating to ENT

* results will be used to better understand the potential for ENT and respiratory irritation, and possibly for determining the possibility of acute/chronic health problems. Results will assist in providing information/recommendations to the public (e.g., what is contributing to irritation, how to reduce exposures)

” to assist in characterizing dust that can become airborne (re-entrainment of settled dust that may be the source of continuing air contamination), and to make recommendations for outdoor dust remediation

4

NYC-WTC_000164789

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000164789Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →