V. Residence Selection/Sampling Rationale
The selection of residential sampling locations will be decided upon by NYC DOH. The general
NYCDOH approach is described as follows: A total of approximately 60 residential units will be
sampled (a unit is an individual apartment or a common area in a multi-apartment building). A
series of three concentric circles is being drawn around the VTC location. These circles will be
divided by direction or zone from the WTC (north, south and west, and east). From five to seven
of the multi-residential buildings will be selected for testing from within each zone.
Testing locations will mainly focus on occupied residences. However, approximately five
imoccupied units nearest the WTC will be targeted for testing. In addition, approximately ten
units will be selected outside of the concentric circles, in neighboring boroughs or communities,
to serve as background sample locations.
Sampling personnel will document the rationale for selecting buildings and residential units for
sampling. They will also document sample locations, conditions during sampling, and possible
interfering factors (e.g., traffic, constniction). In addition, unit occupants and building
owner/operators will be requested to provide information that will better assist in evaluating the
results. Section VII of this plan contains the information needed/requested.
It should be noted that types of contaminant/materials and their concentrations may vary as the
distance of the residence fi-om the WTC increases.
VI. Sampling/Analysis Approach:
1.Indoor
Air and dust sampling will focus on both common/high traffic areas of the building (e.g., lobbies,
front entryways) and on a selected number of apartments/units in the building. Attempts will be
made to select apartments/units where dust is visible as well as units where dust is not visible.
Selecting entryways and common areas should be representative of worst case conditions for
contaminant/material track-in from outdoors. Selecting several apartments/units in the same
building-with and without visible dust-should provide information on the ranges of
contaminants found in indoor living spaces.
If the building is unoccupied, aggressive (leaf blower, high-power fan) indoor air sampling
should be conducted. If the building is occupied, air sampling should be conducted with the
building/unit HVAC system’s fan in continuous operation. After sampling is completed, filters
for the HVAC system, if applicable, should be inspected. If dust is present, recommend filter
replacement.
Indoor air sampling for asbestos will be conducted and analyzed using NiOSH method 7400. If
an action level is exceeded su’;sequent filter analysis using NIOSH 7402 to determine if the
fibers present are asbestos will be conducted. Respirable crystalline silica will be sampled and
analyzed using NIOSH method 7500. Air sampling for inhalable, thoracic, and respirable size
Page 5 of