NYC-WTC_000138659
Circulation of latest draft cleaning and monitoring statement of works for WTC for review and comment.
9 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗Contractual agreement establishing an independent firm to monitor debris cleanup and conduct air sampling.
NYC-WTC_000140593–000140599Folder label: “SCOPES OF WORK IN DOOR AIR & CLEANING”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
‘i.
b) All surfaces must be completely dry prior to the start of sampling.
c) Sampling equipment shall be placed at representative locations within the work area and away from obstructions. The sampling cassette must be placed on a tripod and not taped to existing surfaces.
d) Air conditioning units where applicable shall be run/operated at least 15 minutes prior to the start of sampling. The air conditioning units shall operate continuously throughout the sampling. HVAC systems shall be in operation during sampling.
e) Forced air equipment (e.g. leaf blowers) may be used only after written authorization by the occupant or his/her authorized representative. The project monitor shall advise the occupant or his/her authorized representative on the advantages and disadvantages regarding the use of the equipment and obtain the individual’s signature authorizing use. The authorization shall provide a summary of the advantages and disadvantages and shall be provided by the USEPA.
Before the start of sampling, forced air equipment (such as a 1 horsepower leaf blower) may be used to direct exhaust air against walls, ceilings, floor, ledges and other surfaces. When directing the exhaust, caution shall be taken to minimize disturbance and potential damage to furnishings and personal belongings.
One 20-inch fan shall be installed per 10,000 cubic feet of room space and run at low speed. The fan shall operate continuously throughout sampling and shall not be turned off until sampling is completed.
f) For studio apartments 3 samples shall be collected. For 1-bedroom apartments and above 5 samples shall be collected. Technicians shall collect a volume of 3000 liters per sample using a flow rate of 10 liters per minute.
g) Samples must be labeled and accompanied with completed chain of custody forms before shipping to the designated laboratory.
5. All information must be maintained on a data based software program that is acceptable to the USEPA. Information in the database shall be updated every 24 hours. The information shall at a minimum include information on scheduling, posting of notices, dates of air monitoring and inspections, results of inspections, sampling results, completion dates, etc.
NYC-WTC_000140595
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000138659
Circulation of latest draft cleaning and monitoring statement of works for WTC for review and comment.
9 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139430
Emails forwarding latest drafts of cleaning and air monitoring scopes of work for review and comment.
9 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000138743
EPA circulates latest draft scopes of work for WTC indoor dust cleaning program requesting comments.
9 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162352
EPA request for review and feedback on draft scope of work documents for WTC cleaning and air monitoring contractors.
9 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139460
Emails forwarding latest drafts of cleaning and air monitoring scopes of work for review and comment.
9 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000161167
Forwarded draft Statements of Work for cleaning and monitoring activities requiring review by noon.
9 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000138626
Distribution of revised scopes of work documents for WTC indoor cleaning and monitoring contracts.
9 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139232
DEP requests review of attached Scope of Work documents for mold remediation and air monitoring contracts.
6 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139209
Administrative notice instructs staff to preserve original World Trade Center documents for potential litigation.
6 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000138918
Internal DEP correspondence discussing EPA draft scope of work for WTC program and clarifying agency roles and responsibilities.
6 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139482
Forwarded revised scopes of work for cleaning and monitoring contracts related to WTC indoor air quality.
8 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000138725
EPA transmits revised scopes of work for WTC indoor cleaning and monitoring contracts to DEP.
9 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000140337
Details project scope for scheduling, coordinating, and monitoring dust and debris cleanup with air sampling from apartments affected by World Trade Center collapse.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000151286
Contract outline defining compliance requirements and personnel qualifications for monitoring debris cleanup and air sampling near the World Trade Center.
Similarity score 0.984 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000147982
A project proposal outlining the timeline, methods, and justification for cleaning HVAC systems in residential units affected by World Trade Center dust.
Similarity score 0.984 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140603
Contract establishing requirements for third-party asbestos monitoring and air sampling in residential buildings.
Similarity score 0.980 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139430
Emails forwarding latest drafts of cleaning and air monitoring scopes of work for review and comment.
Similarity score 0.977 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000138626
Distribution of revised scopes of work documents for WTC indoor cleaning and monitoring contracts.
Similarity score 0.977 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000140995
Press release announcing joint EPA and OSHA environmental monitoring data collection at the World Trade Center site.
Cited alongside this record in an Ask answer
NYC-WTC_000141247
Matrix section addressing monitoring and scheduling components of EPA and NYC indoor air activities.
Cited alongside this record in an Ask answer
NYC-WTC_000141307
Cost matrix form documenting EPA and NYC programs, funding sources, and costs for WTC cleanup.
Cited alongside this record in an Ask answer
NYC-WTC_000141313
Cost matrix form documenting EPA and NYC programs, funding sources, and costs for WTC cleanup.
Cited alongside this record in an Ask answer
NYC-WTC_000141322
Detailed cost and activity matrix with comments for EPA/NYC WTC cleanup programs.
Cited alongside this record in an Ask answer