NYC 9/11 Public Portal Document
In the event that mold is observed in a residence during the pre-cleaning inspection, the
Monitoring Contractor will contact the NYCDOH and EPA.
'eliverables
The Project Monitor shall record if mold is present and notify the NYCDOH and EPA. This
information shall be provided via EPA Indoor Air web database or an agreed ij|©n alternative
electronic format or website approved by EPA within 24 hours ofactivity
A
The Project Monitor shall schedule and oversee the cleaning opera the Cleaning
Contractor. No residential, common space or system shall be clean il the exterior
of the building has been cleaned or approved by EPA . lf<Ocheduling SOW cm arises the
Project Monitor should contact EPA. The Project: Monitor shall coordinate daily access for
cleaning and sampling with residents, owners, the Cleaning Contractor and sampling
technicians.
The Monitoring Contractor shall provide st icient personn« :o provide periodic (3-
4hours/unit) oversight of the Cleaning CpiilB Mk verify that K is being conducted in
accordance with the Cleaning Contac^^^^'l
The Project Monitor shall verify that the r is using properly trained and
certified NYSDOL and NYC^F certified workers.
The Project Monitor shall conduct routine quality assurance inspections during the course of
cleaning and concur by initialing the Cleaning Checklist (to be developed) for tasks completed
satisfactGrily.
..
'eliverabL
■
TheProjeci .tor shall review all deliverables prior to submission to EPA. The review shall
assure that lelivefable is accurate and complete, technically sound, and free of clerical
em>rs.
The Project monitor shall submit the completed Cleaning Checklist via F2L or an agreed upon
Jill
Illi alternative electronic format or website approved by EPA within 24 hours of activity.
■^Monitor shall perform a final visual inspections upon completion of the cleaning.
iifeas are not dust free then the Project Monitor will direct the Cleaning Contractor to
reclean as necessary. If all areas are dust free then the Project Monitor will authorize final air
sampling. Final inspections shall be documented using the Cleaning Checklist.
Deliverables
NYC-WTC_000139493
OCR can misread numbers and units. Confirm readings against the page image before using them.