HVAC consulting services invoice, NYC WTC site, 2003

Machine-extracted title · confidence 95%

Invoice for HVAC consulting services provided at the World Trade Center site in 2003.

NYC-WTC_000135339–000135553
Page image
Scanned page image, NYC-WTC_000135463
OCR text

OCR status: ocr · source: ours

C 9/11 Public Portal Document ; NY £-<____viechanical Exhaust System Visual Inspection Form Page 1 of 1 Mechanical Exhaust System Identification: . MECHANICAL ExHAUST FAN HZ Location: Area Served: G- Rack -250 ALBANY erPzey Jers deere to 15 @ Pestmoose st Associated mechanical room: clean YON dry Y___N stored chemicals/refuse Ys Surface : Component System Components Dust/ wic © not present {NOTE: if component not present (NP), not found (NF) or inaccessible (D please Debris Dust ® not found indicate in last column] Present? | Present? | inaccessible Exhaust air outlet: Location: Accessible for inspection? Y N (explain): ; ~_louvers. grates and/or screens y ¥ — outside air duct : Y y — outside air damper(s) N p Exhaust fan unit: ~_blower assembly incl. blower wheel, housing, air vanes, in-line noise attenuators Y Y ~ blower housing acoustical lining Y y ~ vibration collars Np Exhaust air distribution: - Exhaust airducts Est. total Inf _'60 No. locations inspected __1 Specify type (circle): (fetal Y fibrous glass ined nee masonry fibrous glass board flex-duct wood Y Y ~ Accessible in-line fire dampers Est. total qy__ {15 No. locations inspected © p ~ Accessible tuming vanes Est. total qty. No. locations inspected NP ~ Exhaust air grilles Est. total qty _ [5 No. locations inspected © Other (specify): . . Other Information: “THE GuTiRe UNIT OF THE FAN 1S oT WOR A) q. General impression (indicate recommendations for cleaning based on finding of WTC dust): — WTC eecAteD DUST WAS OBSERVED INTHE COLIPODEANS OF THE TAA) ABOVE AWD Betow “He LouveRS. x «= WTC RetaTes DUET WAS CRSERVED INTHE DUCTWORK Cleaning, RR WTC eeated Dust 1S Récourenntn - CLEAN “tHE CoHPONEMTS OF THE FAN AND MTS AsspciATED Docu. KEY: NP = not present; NF = not found; J= inaccessible; U = unknown NYC-WTC_000135463

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000135463Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →