Machine-extracted title · confidence 90%

Form documenting visual facade inspections and air monitoring status for a building at 320 Albany Street.

NYC-WTC_000116169–000116225

Folder label: “320 ALBANY STREET 000301, 16/7502

Page image
Scanned page image, NYC-WTC_000116174
OCR text

OCR status: ocr · source: ours

NYC 9/11 Public Portal Document 2,2 Mechanical Exhaust System Visual Inspection Form Mechanical Exhaust System Identification: Location: MECHANICAL EXHAUST FAN#Z MAIN ROOF - 300 ALBANY PIRZET Associated mechanical room: clean__Y_ dry. _Y _N Area Served: stored chemicais/refuse_ Systern Components [NOTE: if component not present (NP), aot found (NF) or inaccessible (*) please indicate in last column] Exhaust air outlet: Surface Dust/ Debris Present? Location: Accessible for inspection? Y N _(explain): - louvers, grates and/or screens - outside air duct - outside air damper(s) Exhaust fan unit: - blower assembly iacl. blower wheel, housing, air vanes, in-line noise attenuators - blower housing acoustical lining - Vibration collars Exhaust air distribution: - Exhaust air ducts Est. total In ft Specify type (circle): 100 metal fibrous glass lined metal No. locations inspected_ 1 masonry fibrous glass board fex-duct wood - Accessible in-line fire dampers Est. total qty - Accessible turning vanes Est. total qty - Exhaust air grilles Est. total qty. Other (specify): No. locations inspected No. locations inspected No. locations inspected O Other Laformation: Y Page 1 of 1 N WTC Dust Present? Component • not present • not found • inaccessible Y Y NP NP NP NP I General impression (indicate recommendations for cleaning based on finding of WTC dust): - WTC RELATED DUST WAS OBSERVED INTHE FAN AND ITS COMPONENAI AND ITS ASSOCIATED DUCTS. - CLEANING 1S REQUIRED FOR WTC RELATED DUST. - CLEAN THE EXHAUST FAN, ITS COMPONENTS AND ITS ASSOCIATED DOCTS. KEY: NP = not present, NF = not found; I = inaccessible; U = unknown NYC-WTC_000116174

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000116174Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →