HVAC component inventory, 300 Albany St

Machine-extracted title · confidence 100%

List of HVAC components including fans, ducts, and mixing chambers at 300 Albany Street.

NYC-WTC_000116323–000116360

Folder label: “300 ALBANY ST 1000436, 16/7504”

Page image
Scanned page image, NYC-WTC_000116332
OCR text

OCR status: ocr · source: ours

NYC 9/11 Public Portal Document 22 Mechanical Exhaust Syste /isual Inspection Form Mechanical Exhaust System Identification: MECHANICAL EXHAUST FAN#6 Location: MAIN ROOF - 300 ALBANY PTRZET Area Served: Associated mechanical room: clean _Y_N System Components INOTE: If component not present (NP), aot found (NF) or inaccessible (") please indicate in last column] Exhaust air outhet: Location: Accessible for inspection? Y V _(explain): stored chemicais/refuse Surface Dust/ ! Debris Present? - louvers, grates and/or screens - outside air duct - outside air damper(s) Exhaust fan unit: - blower assembly incl. blower wheel, housing, air vares, in-line noise attenuators - blower housing acoustical lining - vibration collars Exhaust air distribution: - Exbaust air ducts Est total In ft 100 No. locations inspected_1 Specify type (circle): fibrous glass lined meta ) magonry fbrous glass board flex-duct - Accessible in-line fire dampers - Accessible turning vanes - Exhaust air grilles Other (specify): wood Est. totai qty Est. total qty Est. total qty. 9 No. locations inspected No. locations inspected No. locations inspected_O Other Iaformation: Page 1 of1 N WIC Dust Present? Component • not present • not fomed • Inaccessible Y NP NP Y NP NP I General impression (indicate recommendations for cleaning based on finding of WTC dust): - WTC RELATED DUST WAS OBSERVED IN THE FAN AND ITS COMPONENT, ANA ITS ASSOCIATED DUCTS. - CLEANING 1S REQUIRED FOR WTC RELATED DUST. - CLEAN THE EXHAUSI FAN, ITS COMPONENTS AND ITS ASSOCIATED DUCTS. KEX: NP = not present; NF = nnt found; I = inaccessible; U = naknown NYC-WTC_000116332

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000116332Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →