11. Bulk and heavily accumulated dust/ debris samples were collected with a disposable plastic
spoon and placed in a re-sealable plastic bag. When accumulations were not great enough to facilitate this
sampling method, tape or a mixed cellulose esther (MCE) filter was swiped over the dust covered surface
to offer an qualitative indication of asbestos presence.
• Analysis of bulk and heavily accumulated dust/ debris samples was conducted by Polarized Light
Microscopy (PLM) in order to characterize the asbestos content of dust/debris samples. Because of the
analytical method used to determine asbestos content in heavily accumulated dust/ debris samples, which
is identical to the method of analysis used for bulk samples, these results are included in the appendix
• under the heading of Bulk Sample Lab Data.
■
■ SECTION 4— DISCUSSION
The discussion below is a summary of air sand bulk sample findings obtained by Hillmann.
■ 4.1 Outdoor Airborne Asbestos Fibers
■ In general, the buildings constituting the World Trade Center did not contain extensive levels of friable
asbestos containing materials at the time of their collapse. Nonetheless, asbestos levels in the air of the
downtown area have been one of the highest levels of concern for health and safety since the World Trade
Center collapse. Hillmann has recently obtained extensive outdoor sampling for asbestos levels in the
• ambient air in Downtown Manhattan for various clients. In the initial days after the collapse of the World
Trade Center levels of airborne asbestos were elevated. However, since that time levels of airborne
• asbestos fibers have been below the EPA NESHAP standard of 0.01 fibers/cc. It is unlikely that outdoor
concentrations of asbestos would lead to the re-contamination of the Financial Center Marriott.
4.2 Indoor Airborne Asbestos Fibers
■ The preliminary assessment of airborne asbestos concentrations at the Hotel was conducted on September
18, 2001. The results of this sampling found fiber concentrations analyzed by PCM to be in excess of the
■ acceptable level of 0.01 f/cc. Those samples analyzed using TEM revealed asbestos structures to be
present in these samples below the concentrations deemed acceptable for re-occupation by New York
■ City standards.
■ Air sampling continued for the duration of the cleanup of Roy's Restaurant, the adjoining kitchen and
adjacent lobby. This cleanup began on September 26, 2001 and continued until September 30, 2001. Air
sampling conducted outside of the work area during the cleanup often indicated fiber levels in excess of
the 0.01 f/cc deemed acceptable by OSHA. TEM analysis of these same samples identified the presence
of asbestos structures among the fibers, but rarely in excess of the 70 structures per mm permissible
under New York City regulation. All of the final air test samples collected after the clean-up was
• complete passed the New York City clearance air quality standard.
After the contractor had completed the clean up of Roy's Restaurant, the adjoining kitchen and adjacent
lobby, the area was inspected by Hillmann's industrial hygienist. Final air tests were conducted inside of
the work area. Four (4) of the five (5) TEM samples analyzed, evidenced no asbestos structures. Less than
10 asbestos structures were identified on the fifth sample. This was well below the asbestos level
acceptable for re-occupancy in New York City.