Re: Environmental Testing Page 3 of 5

The 41 µg/ft2 sample was taken from glass table top in Room 527. The room a

window was left open during the disaster and the floor and room contents are covered with dust. The 69 µg/ ft2 sample was taken from the vinyl flooring in the southwest corner of the second floor.Again, windows were left open and the floor and office contents are covered with dust. This testing indicates that significant lead contamination is not a problem in the building. The affected areas require some cleaning, which is discussed later in this report.

Asbestos Air Samnlin

10 air samples (one per floor) were taken and analyzed by an accredited asbestos laboratory using transmission electron microscopy (TEM) TEM analysis is accurate for finding even trace amounts of asbestos fibers very

present in the air.

The United States Environmental Protection Agency (EPA) has established a protocol for determining whether school areas are safe for re-occupancy after completion of asbestos abatement projects. This procedure is covered by EPA 40 CFR Part 763, Asbestos-Containing Materials in Schools. The procedures state that the average asbestos airborne fiber level in the abated work area must be less than 70 asbestos structures per square millimeter (AS/mm2).

The laboratory results from the testing on September 25, found no asbestos structures present in 8 of the samples. 2 samples had one asbestos structure (fiber) present and the levels were well below the allowable 70 AS/mm2. Reference the attached laboratory results from EMSL Analytical.

Very low levels of asbestos exist in the New York City urban environment. Two samples with one asbestos structure present in a total sampling of 10 is considered statistically insignificant.

HVAC Asbestos Sampling

The air handling units have not operated since the morning of September 11, 2001. Dust samples were taken in the immediate vicinity of the air handling unit outdoor air intakes on each floor. A total of 23 samples were analyzed by the accredited asbestos laboratory using polarized light microscopy (PLM).

NYC-WTC 000119404

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000119404Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →