NYC-WTC_000125653
Report detailing asbestos inspection results for the 130 Cedar Street site.
17 shared non-person entities · Same agency, volume and box · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗Cover page for a survey report detailing asbestos and lead-based paint findings at 130 Cedar Street.
NYC-WTC_000125204–000125524Folder label: “130 CEDAR STREET”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Asbestos and Lead Paint Inspection Report for 130 Cedar Street, New York, NY 10006
is 2.1 ASBESTOS INSPECTION & BULK SAMPLING PROCEDURES:
The asbestos inspection procedures were based on the guidelines established by the Asbestos Hazardous Emergency Response Act (AHERA), as set forth in 40 CFR Part 763 of October 30, 1987. The AHERA guidelines represent the most up-to-date inspection and sampling protocol available and as such were utilized during the inspection and sampling. For the purposes of this inspection, suspect ACM has been placed in three (3) material categories: Thermal Systems Insulation (TSI), Surfacing Materials and Miscellaneous Materials.
All accessible areas of the building at 130 Cedar Street were inspected physically, functional space by functional space and homogeneous area-by-homogeneous area to determine the presence or absence of asbestos-containing materials. No demolition was done for sampling purposes because the facilities are fully operational and are currently being used by building occupants. Electrical wiring insulation was not sampled or inspected because electric power could not be shut off.
Suspect materials that may be present inside wall cavities, electrical wiring or which were otherwise inaccessible were not included in the scope of this inspection. Core samples of friable and non-friable suspect materials were collected by penetrating the suspect material to its substrate. The bulk samples collected were placed in sealed containers, labeled with an identifying code and a sample log was kept. Representative samples of each sampling area were then submitted to the laboratory to be analyzed for asbestos content. The inspection Involved the following tasks:
1. A visual determination as to the extent of visible and accessible suspect materials and conditions of the material. 2. Collection of suspect building materials for asbestos content. 3. All suspect friable and nonfriable materials were quantified in their respective locations. 6. All suspect materials sampled were identified on the appropriate building floor plan diagram with an identifying sample number. 7. A Chain of Custody record was prepared to accompany bulk samples to the laboratory.
The assessment process includes classifying the material as Friable ACM or Non-Friable ACM. Friable ACM is the term given to any material that contains more than one percent (1%) asbestos by weight and can be crumbled, pulverized, or reduced to powder by hand or mechanical pressure. The word "Friability" refers to a material's likeliness to release airborne fibers when in situ, or under mechanical pressure. There is a greater possibility that a friable material will release fibers into the air when disturbed than will a non-friable material (i.e., floor tiles, roofing materials, etc.) thereby causing a potential hazard.
•
Prepared for Masterworks Development Corp. By JLC Environmental Consultants, Inc. Project No. 04-3271 Page 6
NYC-WTC 000125211
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000125653
Report detailing asbestos inspection results for the 130 Cedar Street site.
17 shared non-person entities · Same agency, volume and box · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125526
Letter reporting bulk dust sample results confirming the presence of asbestos-containing materials at 130 Cedar Street.
20 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000123797
NYC DEP letter to building owner requesting environmental hazard assessments and bulk sample results for WTC-area building re-occupancy.
23 shared non-person entities · Same agency, volume and box · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000095478
Cover page for an air monitoring and bulk sampling report for Building #200 at 375 South End Avenue.
21 shared non-person entities · 1 shared topics · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000113372
Fax cover sheet from Alchemy Properties Inc. dated February 19, 2002, regarding records for 38 Warren Street.
17 shared non-person entities · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗12 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000104679
Report detailing dust sampling from hospital entrances to determine asbestos content following the September 11 attacks.
10 shared non-person entities · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000099164
Letter from DEP Commissioner regarding exterior survey findings of WTC debris and removal efforts at the landmarked building.
6 shared non-person entities · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000131928
Fragmented document page from the Department of Environmental Protection archive.
14 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000109972
Fax cover sheet transmitting asbestos bulk samples from Fiterman Hall to Applied Technology Services for analysis.
5 shared non-person entities · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120940
Document tracking environmental samples collected from Building #100 at 345 South End Avenue on October 22, 2001.
16 shared non-person entities · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120991
Record documenting the transfer and custody of air samples from Building #100 at 345 South End Avenue collected on October 22, 2001.
15 shared non-person entities · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000105069
Cover letter enclosing air and bulk sampling results for 86 Trinity Place, 22 Thames, and 65 Broadway.
Similarity score 0.951 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000096158
Fax cover sheet from Tenants & Neighbors dated July 19, 2002 regarding 105 Washington Street.
Similarity score 0.950 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000176137
Summary report detailing air and settled dust sampling results from a residential building, including methods for fiber analysis.
Similarity score 0.950 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.950 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000095120
Chain of custody document for air and bulk sampling results at the Exchange site dated October 2001.
Similarity score 0.950 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000095084
Letter from American Stock Exchange enclosing air and bulk sampling reports for Trinity Place properties dated late 2001.
Similarity score 0.948 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000125579
Technical specifications document prepared for asbestos abatement work at the 130 Cedar Street site.
Cited alongside this record in an Ask answer
NYC-WTC_000125098
Protocol document outlining air sampling and monitoring procedures for 130 Cedar Street.
Cited alongside this record in an Ask answer
NYC-WTC_000125653
Report detailing asbestos inspection results for the 130 Cedar Street site.
Cited alongside this record in an Ask answer
NYC-WTC_000151548
OSHA letter to the EPA providing a description of asbestos monitoring data used for selecting personal protective equipment for cleanup contractors.
Cited alongside this record in an Ask answer
NYC-WTC_000151555
EPA Region 2 responds to a congressional inquiry about the joint EPA-DEP program for testing and cleaning lower Manhattan homes after the WTC collapse.
Cited alongside this record in an Ask answer