Asbestos and Lead Paint Inspection Report for 130 Cedar Street, New York, NY 10006

51.Multi-Colored Pipe Wrapping 52.Lintel Caulking 53.Cap Flashing Caulking 54.Roof Membrane 55.Roofing Fill 56.Screed Coat 57.Flashing Tar 58.Packed Cardboard Pipe Insulation 59.Inner lining to Packed Cardboard Insulation 60.Parapet Wall Stucco 61.Bulkhead Exterior Door Caulking 62.Bulkhead Flashing Tar 63.Tar Paper over Plywood 64.Bulkhead Tar 65.Duct Vibration Reducer Cloth 66.Pitch Pocket Tar 67.Water Tower Roof Shingle 68.Ceiling Tile Debris 69.Interior and Exterior Caulking on Aluminum Frame Windows 70.Electrical Wire Insulation 71.Electrical Panel Board fl 72.Stairwell Bulkhead Skylight Caulking/Tar 73.Exterior Loading Dock Door Frame Caulking 74.Exterior Expansion Joint Caulking on Sidewalk 75.Elevator Break Pads

2.4 SUMMARY OF FINDINGS FOR ACM:

Bulk samples of suspect materials were collected and analyzed using Polarized Light Microscopy (PLM) and Transmission Electron Microscopy Methods the following materials were confirmed, or assumed, to contain greater than one percent (1%) asbestos and are therefore classified as ACM.

1. Exterior Window Putty on Factory Windows 2. Interior Window Putty on Factory Windows 3. Exterior Window Caulking on Factory Windows 4. Old caulking behind aluminum window frames at North and South elevations 5. Pipe and pipe fittings insulation throughout building 6. Chimney access door frame caulk 7. Interior boiler lining (assumed ACM at Boiler 2) 8. Perimeter waterproofing tar (tank room in boiler room) •

Prepared for Masterworks Development Corp. By JLC Environmental Consultants, Inc. Project No. 04-3271 Page 10

NYC-WTC 000125215

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000125215Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →