130 Cedar Street July 15, 2004 Carpentry

C. Bolts: Standard mild steel, square head machine bolts with square nuts and malleable iron or steel plate washers or carriage bolts with square nuts and cut washers conforming to the following:

1. Bolts: FS-FF-B-575 and 584.

2. Nuts: FF-N-836D.

3. Expansion Shields: FS-FF-B-561.

4. Toggle Bolts: FS-FF-B-561.

5. Lag Screws and Botts:_ FS-FF-B-561.

D. Wood Screws: Per Fed. Spec. FF-S-111 D.

E. Concrete and Masonry Anchors: Standard expansion shield self-drilling type concrete anchors where so shown or noted on the drawings, or where approved by Architect. PART 3.00 - EXECUTION

3.01 INSPECTION

A. Examine the areas and conditions where carpentry is to be installed and notify the Architect of conditions detrimental to the proper and timely completion of the work. Do not proceed with the work until unsatisfactory conditions are corrected to permit proper installation of the work.

3.02 INSTALLATION OF FINISH HARDWARE

A. All finishing hardware specified In Section 08700 of this specification entitled "Door Hardware" shall be received, accounted for, stored and applied under this Section.

B. Hardware shall be sorted and stored in space assigned by Contractor and shall be kept at all times under lock and key. The safety and preservation of all items delivered will be the responsibility of the Contractor.

C. Hardware shall be carefully fitted and securely attached, in accordance with these specification and the Instructions of the various manufacturers.

D. Unless otherwise noted, mount hardware units at heights established in Section 08100.

E. Install each hardware item in compliance with Manufacturer's Instructions and recommendations. Wherever cutting and fitting Is required to install hardware onto or Into

surfaces which are later to be painted or finished in another way, install each item completely and then remove and store In a secure place during the finish application. After completion of the finishes, re-install each Item. Do not install surface-mounted items until finishes have been completed on the substrate.

F. Set units level, plumb and true to line and location. Adjust and reinforce the attachment substrate as necessary for proper Installation and operation.

G. Drill and countersink units which are not factory prepared for anchorage fasteners. Space fasteners and anchors In accordance with industry standards.

06200-4

NYC-WTC 000125194

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000125194Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →