NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/7DCAS/WTC/PA TAA: Application forums
Document / 26 pages

Milo Kleinberg Design Associates fax cover sheet, July 17 1997

Machine-extracted title · confidence 95%

Fax cover sheet from Milo Kleinberg Design Associates dated July 17, 1997, regarding WTC/PA TAA application forms.

NYC-WTC_000168166–000168191

Folder label: “WTC/PA TAA: Application forums

Page image
Scanned page image, NYC-WTC_000168178
OCR text

OCR status: ocr · source: ours

NYC 9/11 Public Portal Document JUL 17 797 @3:43PM SILVERSTEIN PROP P, m 07/17/97 THU 11:32 TEL 212 725 0383 MILO KLEINBERG 007 .» WAY-23-1997 12:88 Pa? Rider “C* Genaral Requirements 10, Upon collecdan ota work, nad trounce of he Fer wo Ossi nt | 1) conmpleen set of i. 13. 14. 15, . The Part Authority maintains a mock of cervala World Trade reproducible Contact film, wash-off type “As-built” drawings ( \wald nat be folded), conformed Specifications, all Shop Drawings, catalog cuu, evc., a: d approved by the responsible ‘ t of Record, must be submirtad to the Worl | Tends Cantar Project Manager. In addition, one (1) expy of the AutoCAD corupatible computa iles that ware used te prepare the drawings shall be submirted on 1.44 Megabyte fleppy dial | 1) for Part Autharity records. ‘The Tenant and his Contractor shall plan and conduct all their opetuzion as to work in harmony with others engaged at the construction sits, and nox w delay, endangw, or ‘a with the operations of others. wt | ard ousserials, which the Contractor may purchase. A complete lic af available materials is i hie from Ms. Pariela Bonny, WC Planning & Design Division, One World Trade Centex, Buite 36 Sav : 1, Talephone: 212-435-7002, It in tha vexponsibility of the Contracrar ro return all World Trade ‘ Building Standard attic stock materials te be salvaged, aa apecified and directed by the Post Au | arity Inspector from The Contractor shal! submit affidavits attesting to the fire ret o ul wooed construction, temperary or perinanent, prior to installation, per New York City Buildi : ¢ Code Section 27-328, to the WIC Supervising Engines, ov to the WIC Conseruction Inspector 2 : pesenting him in the field. The following criteria shall be adhered ro for all new electri | hon | curler coring of floor slabs in any World Trade Center building: a) All coring through floor clabs shall be strictly in acoordance with Po | Authority coring eriteris standard drawings 8-CI, §-C2 and 8-CS. | b) The Tenant’s Congultanr shall ssie vo the Port Anthaiey n axl : ve drawing with al! Tenanr Alteration Applications that require coring to be performed. The dre | ing(s) aholl encompass the eqtire damised leazehold where coring wark is axtensive, Each | ole shall be identified as w new, existing, active, abandoned, abandoned and filled, ete., the ; sball be located with dimensiaas. Sizes af carts shall also be indicared. Where coring is re | sired in canjunction with 4 “Tenant Alteration Application of « minor nature, adjacent existing ¢: | es abel be idencified and located by dimensions un the core drawing. c} All floor. cutlets ta be removed, or abandoned, sball have sll power wii 1g and cables removed back The after-set fietings shall be removed and filled in accordance ye: iremens af “a” above d) When removing unused, or abandoned communication cables, the ci | les chull he removed from tha cells al] the way back to the binding pena in the Telephona Clos: is. | a) Upon verification that communication equipment in telephone Closet : is completely abandoned, 16, contractor shall remove frames, eard holders and miscellanséuy inac |v equipment as well. Core drilling and the shooting of studa into slabs, atc_, with the us | af p: iver actuated fasteners, - pneumatic and electrical handlers, or any other acise producing equipm it,shal be permirtad arly between the hours af 6:00 PM and 8:00 AM. Further, en observer ia req: red an the flour below ta check for water leakage during the core drilling operation. In the event | :» Contructor je engaged in ' any other “noisy” operations, whieh disturb adjacent Tenant(s) operatic |, the Pert Authority, at its sole discretion, may require the Contractor to perform eaid “noisy” eperati 1s during non-business haurs. | _ Page 2/7 06/23/97 FRI 11:1: ([TX/RX No 9992) NYC-WTC_000168178

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000168178Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000168193 · Box 7DCAS

Fax cover sheet from Milo Kleinberg Design Associates dated July 17, 1997, listing TAA application forms and riders.

Filed in the same folder

Compare copies and versions →