Document / 26 pages

Milo Kleinberg Design Associates fax cover sheet, July 17 1997

Machine-extracted title · confidence 95%

Fax cover sheet from Milo Kleinberg Design Associates dated July 17, 1997, listing TAA application forms and riders.

NYC-WTC_000168193–000168218

Folder label: “WTC/PA TAA: Application forums

Page image
Scanned page image, NYC-WTC_000168209
OCR text

OCR status: ocr · source: ours

NYC 9/11 Public Portal Document JUL 17 ’S7 @3:14PM SILVERSTETN PROP pg 07/17/97 THU 11:34 TEL 212 728 0398 MILO KLEINBERG as jo09 MOY=23+-1997 12:@1 P. Rider “C" ; Life Safety Sysiems | e) Prior to eccupancy of the promises, and prior ca issuance of « Gerti{ | ate of Completion the Tanant shall furnish to the WTC Supervising Enginesr, 2 copy of an | xecuted Agratmant between | the Tenant and » Contractor who ahall ba responsible for inspection | nd msinm@asnes, a2 required ° hy the New York City Fire Prevendon Code of each new and/ar exis ing tenant life sefery system, including but not limited to, smeke detection, pre-action ler » ‘ems end Halos suppression systema, This Agreement may ne be cancdled, terminated, or medifi || without written advance request to the Port Authority . The Agreement. between the Tenanr and the Contractor shall id) that the Gontrector ix approved by the city of New York to perform such maintenance and | aspectinn functions; thet the Contractor will furnish copies of all periodic tests to the Post Autha: | y Coordinaur, Fire Safety Programs; that the Conwactor will furnish copies of any rea ag :sments at least 15 days pricr t» axpirution and will notify the Part Acthority Coordinator, Fs Gufety Program, ia the event that the Agreemant hos been agneeled. 19. The Connractor shall mark the location af amales desemnts installed on the undervide of the eailing tiles. The pina may be ebtained from C : wasions ar the B-2 Level. For smnoles detectors located below the raisssl Boars, the Contractor shall t it locations with diztinctive eolared pushypins on the ceiling directly above the detectors, or mount on tt | wall within the room, a partial floor plan showing the raised floor trea with dimensioned locations t eath smoke detector ¢ ings wich enlored push-pins 20. It ia required that existing demising walls ba checked for penetrations ay. sealed fo remtere their fire rating. In addirian, all existing structural steal firepronfing must b4 pate sd where material is missing, as required by the WIC Supervising Engineer. The marerials ui | d for sealing penetrations and patching firepoafing shall be as approwed by the Port Authority. 21, Ic shall be the reaponsibility of the Tenants consultant to eee to it chat the ‘Mowing requirement ix met: All electrical werk ta be performed, including ull electrical devices fo wh ih, or from which, any slestrical connection, or discannections are to be, made, shall be a) the Electrical Drawings. 22. The Contractor shall remove all electrical devices, including all conus ‘nd wizing specified on the drawings, to be no longer in use. 23. Materials containing PVC will not be permitted in any permanent ¢enet | sien except for carpeting and underlayment. | 24, The Tenant's Consultant shall submit for review and approved by the Pe |: Authority catalog cuts for all new electrical panels and new circuit breakers whieb shall indicgte th |; they are U,L. listed. In addition, whenever circuit breakers are te be installed in existing pancls, \¢ in panels nor made by the esircuit breaker manufacturer, auch circuit breakers shall be U.L. if: ; for use in lead centers and panel-boards manufactured by othen, Special Requirements B. The following [terns numbers 25 through 35 art net applicable t Communi: | tions Systema installations. 25. All permanent leck-ceww, keying, #te., must be of the “Corbin” system an | must sanfarm with Port Authority requirements regarding stamping and keying of master ring cy . anders having the Port Authority key-way. Is ia required that the Tenant purchase all their/cylio (2 from the Port Authority. The Contractor must contact the World Trade Center Leckamith Sijop. EF : ur World Trade Center, 4th Floor, Telephone: 212-435-3182. Page 4/7 ( 06/23/97 FRI i1:. (TX/RE NO 9962] NYC-WTC_000168209

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000168209Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Lease Agreement for 7 WTC, Mar 1998 · Box 7DCAS

NYC-WTC_000169723

Official lease agreement between the City of New York and 7 World Trade Company, L.P. for space at 7 World Trade Center.

6 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.937

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000168166 · Box 7DCAS

Fax cover sheet from Milo Kleinberg Design Associates dated July 17, 1997, regarding WTC/PA TAA application forms.

Filed in the same folder

Compare copies and versions →