130 Cedar Street July 15, 2004 Selective Demolition and Façade Restoration Koenen Associates

covering on newly installed work where reasonably required to ensure freedom from damage or deterioration at time of substantial completion; otherwise, clean and perform maintenance on newly Installed work as frequently as necessary through remainder of construction period. Adjust and lubricate operable components to ensure operability without damaging effects.

F. To extent possible through reasonable control and protection methods, supervise performance of work In a manner and by means which will ensure that none of the work whether completed or in progress, will be subjected to harmful, dangerous, damaging, or otherwise deleterious exposures during construction period. Such exposures include (where applicable, but not by way of limitation) static loading, dynamic loading, internal pressures, external pressures, high or low temperatures, thermal shock, high low humidity, air contamination or pollution, water, Ice, solvents, chemicals, light, radiation, puncture, abrasion, heavy traffic, soiling, bacteria, insect infestation, combustion, electrical current, high speed operation, Improper lubrication, unusual wear, misuse, incompatible interface, destructive testing, misalignment, excessive weathering, unprotected storage, improper shippingthandling, theft and vandalism.

G. Require Installer of each major unit of work to inspect substrate to receive the work, and conditions under which the work will be performed, and to report (in writing to Contractor) unsatisfactory conditions. Do not proceed with the work until unsatisfactory conditions have been corrected In a manner acceptable to Installer.

H. Where Installations Include manufactured products, comply with Manufacturer's applicable Instructions and recommendations for installation to whatever extent these are more explicit or more stringent than applicable requirements indicated in the Contract Documents.

I. Inspect each item of materials or equipment immediately prior to installation and reject damaged and defective items.

J. Provide attachment and connection devices and methods for securing work properly as it is Installed; true to line and level, and within recognized industry tolerance if not otherwise

indicated. Allow for expansions and building movements. Provide uniform joint widths in exposed work, organized for best possible visual effect. Refer questionable visual-effect choices to Architect for final decision.

K. Recheck measurements and dimensions of the work as an integral step of starting each installation.

L. Install work during conditions of temperature, humidity, exposure, forecasted weather, and status of project completion which will ensure best possible results for each unit of work in coordination with entire work. Isolate each unit of work from non-compatible work, as required to prevent deterioration.

M. Coordinate enclosures.(closing-in) of work with required inspections and tests, so as to avoid necessity of uncovering work for that purpose.

N. . Mounting Heights: Except as otherwise Indicated, mount individual units of work at industry-recognized standard mounting heights, for application indicated. In CMU walls mount units at height closest to Manufacturer's recommendation so as to minimize cutting of block coursings. Refer questionable mounting height choices to Architect for final decision.

END OF SECTION

I Materials and Equipment 1600-4

NYC-WTC 000125144

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000125144Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →