NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 50/130 CEDAR STREET
Document / 105 pages

Air sampling protocol document, 130 Cedar Street, Jan 2005

Machine-extracted title · confidence 100%

Protocol document outlining air sampling and monitoring procedures for 130 Cedar Street.

NYC-WTC_000125098–000125202

Folder label: “130 CEDAR STREET

Page image
Scanned page image, NYC-WTC_000125119
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

130 Cedar Street July 15, 2004 Selective Demolition and Façade Restoration Koenen Associates

4. Shop drawings for each Section of the work shall be numbered consecutively, and the numbering system shall be retained throughout all revisions. Each drawings shall have a clear space for the stamps of the Contractor, Architect, S and one of the Architect's consultants.

5. All shop drawings shall be thoroughly checked by the Contractor for compliance with the Contract Documents before submitting them to the Architect and shall bear the Contractor's stamp of acoroval certifying that they have been so checked. Any shop drawings submitted without this stamp of approval and certification, and shop drawings which, In the Architect's opinion, are incomplete, contains errors or have not been checked, or only checked superficially, will be returned unchecked by the Architect for re-submission by the Contractor.

6. In checking shop drawings, the Contractor shall verify all dimensions and field conditions and shall check and coordinate the shop drawings of any Section or trade with the requirements of all other Sections or trades whose work is related thereto, as required for proper and complete installation of the work. The Architect will review shop drawings. The Architect's acceptance of shop drawings is for design only and not method of assembly or erection. Acceptance shall in no way be construed as (1) permitting any departure whatsoever from the Contract Documents; (2) relieving the Contractor of full responsibility for any error in details, dimensions, omissions, or otherwise that may exist; (3) relieving the Contractor of full responsibility for adequate field connections, erection techniques, bracing, or deficiencies in strength; (4) relieving the Contractor of full responsibility for satisfactory performance of all work and coordination with the work of all subcontractors and other contractors; or (5) permitting departure from additional details or Instructions previously furnished by the Architect. Acceptance of such drawings shall not be construed as a complete check, nor shall it relieve the Contractor from responsibility for proper fitting of the work, nor from the necessity of furnishing any work which may not be indicated on shop drawings when approved. The Contractor shall be solely responsible for any quantities which may be shown on the shop drawings.

7. No work shall be fabricated, manufactured, or installed from shop drawings stamped "Revise and Resubmit" or "Rejected", and such shop drawings shall be corrected and resubmitted by the Contractor until accepted by the Architect. At least one complete set of "No Exceptions Taken", Make Correction Noted" or "In General Conformance With Design Concept", "In General Conformance With Design Concept Except As Noted" shop drawings shall be kept at the site in the contractor's field office for reference at all times. "Revise and Resubmit" or "Rejected" shop drawings shall not be permitted at the site.

8. Submittals marked "No Exceptions Taken" or "In General Conformance With Design Concept":

a. Submittals which require no corrections by the Architect will be marked "No Exceptions Taken" or "In General Conformance With Design Concept".

9. Submittals marked "Make Corrections", "Noted" or "in General Conformance With Design Concept Except As Noted": a. Submittals which require only a minor amount of correcting shall be marked "Make Corrections Noted" or "In General Conformance With Design Concept Except as Noted". This mark shall mean that checking Is complete and all corrections are obvious without ambiguity. Fabrication will be allowed on work marked "Make

Submittals 01300-2

NYC-WTC 000125119

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000125119Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →