NYC 9/11 Public Portal Document
Mr. Shaun Hession
. New York City Housing Authority
November 12, 2001
ENTEQUE Page 2
and Administrative
Department of Environmental Conservation (NYSDEC) Technical levels do not
While the TAGM
Guidance Memorandum (TAGM) Soil Cleanup Levels. standard for
risk-based
apply except in soil contamination, these standards provide a The sampling was
contamination in bulk material, allowing a means of comparison. the presence and
determine
designed and conducted as a preliminary assessment to
extent of contaminants within the dust and debris present within the formerly occupied
collapse of the World
space. These contaminants are suspected to exist due to the the subject property. The
within
Trade Centers and the associated fires both outside and
intent of determining the extent and levels of contamination, if present, was to make
files, paperwork,
initial recommendations concerning the removal and recovery of
computer equipment, personal items, etc.
cleanup, EMTEQUE has relied
In discussing the issues of contamination and potential experience, and standards
heavily on general industrial hygiene practices, professional
matter.
that, in our opinion, most closely relate to the current subject
floors. Bulk and wipe
Sampling for all contaminants was conducted th roughout the present at each
debris
sampling was conducted based upon the level of dust orsufficient material was able to be
sampling location; bulk sampling was conducted where
order to determine if
collected for laboratory analysis. The sampling was conducted inAs such, sampling was
contamination was localized or distributed throughout the floors.
appearance) and then in
conducted in the dirty and clean areas (based upon physical
the areas showing the tapering off of dust and debris.
A to this report. Copies of
A summary of all sampling results is included as Attachment Attachment B to this report.
drawings showing all sampling locations are included within
Attachment C to this report.
Copies of all analytical results are included within
Asbestos
analysis for asbestos. Analysis for
A mixture of bulk and wipe samples were obtained for
an independent American
asbestos was conducted by EMSL Analytical, Inc. EMSL Is Department of Health
Industrial Hygiene Association (AIHA) and New York State Analysis was
Environmental Laboratory Accredited Program (ELAP) laboratory. staining.
dispersion
conducted utilizing Polarized Light Microscopy (PLM) via
the exception of the three
A"total of nine samples were collected from each floor with samples from the 10th
samples collected from the partially occupied 7th floor and ten
floor. This yielded a total of 67 samples.
the 67 samples collected.
Sample results indicated the presence of asbestos in 23 of from all floors. The
observed
Samples Indicating the presence of asbestos were
asbestos analytical results appear to Indicate that the dust and debris may not be
a visual observation.
homogeneous despite the material appearing homogenous from
•
NYC-WTC 000124615
OCR can misread numbers and units. Confirm readings against the page image before using them.