Deo 07 01 OS:lap Rirtek Environmental Corp °: t 12)768-0759 rt p:9 1t

8.11 All contaminated materials be stored in a securely locked dumpster or storage shall

area. The dumpster or storage area must be approved by the Environmental Consultant prior to its use.

8.12 The container used for the storage of bagged contaminated waste shall be an enclosed dumpster. The dumpster shall have a solid metal roof and a door with a solid

metal

padlock. No unbagged contaminated waste shall be stored in time dumpsters. The Contractor ensure that all bags and drums placed in the dumpster are undamaged. shall

8.13 The Contractor shall provide a secured storage area for the storage of packaged contaminated waste prior to the transport to the waste site. The storage area shall be equipped with lockable doors

8.14 All waste shall be disposed of at an approved landfill as construction debris.

9.0 WORK AREA CLEARANCE

9.1 The abatement work area is cleared when the work area is visually clean and clearance air testing for ACM indicates that airborne asbestos fiber concentrations are below 70 s/mm2.

9.2 In the event that release criteria is not met, all costs associated with re-testing and re- cleaning shall be borne by the Contractor.

9.4 Clearance Air Monitoring and Analysis by TEM

a. Acceptance Criteria: Decontamination of the work meets the requirements of site

this test when every work area sample indicates an airborne concentration of fibers of less than 70 structures per

squared. If any sample is above millimeter

this clearance level, then the decontamination is incomplete and the work area shall be re-cleaned.

END

ATTACHMENTS TO THESE PROCEDURES WILL INCLUDE THE FLOOR PLANS SHOWING THE AREAS AND EXTENT OF CLEANUP REQUIRED BASED ON BULK SAMPLE TESTING PERFORMED ON EACH FLOOR.

Airtek lavbmmental Carp. PAGE 8 Legal Aid Society 90 Church Street

NYC-WTC 000124628

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000124628Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →