NYC-WTC_000128550
Asbestos inspection report notification form submitted to NYC DEP for 102-104 Greenwich Street.
17 shared non-person entities · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Facsimile cover sheet transmitting documents regarding environmental work at 102 Greenwich Street.
NYC-WTC_000104853–000104885Folder label: “102 GREENWICH STREET Block: 53 Lot: 37 BIN:1001054 104 Greenwich Street”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
9. Polyethylene sheeting shall be used to isolate contaminated from uncontaminated areas. This polyethylene sheeting shall be replaced or repaired immediately if torn or damaged. One layer of polyethylene sheeting shall be required for walls and two layers of polyethylene sheeting shall be used to seal open space between work areas and non-contaminated areas and for all floors. In buildings required by the Uniform Construction Code to be of noncombustible construction, all materials used to construct separation barriers must meet the Uniform Construction Code, building sub code requirements for that building and all plastics used must be flame resistant.
B. PROPER METHODS OF REMOVAL AND HANDLING FOR LARGE, SMALL AND MINOR ASBESTOS ABATEMENT PROJECTS
1. Initial activity in the work area shall be conducted in the following order:
a. Remove filters from all heating, ventilating, and air conditioning systems. Wet the filters and place them in polyethylene bags, double bagged with visible labels, for disposal as asbestos-containing waste. Squeeze all excess air out of the bag before sealing to prevent puncture during disposal. Secure bags by twisting, taping, folding over, and scaling them with duct tape.
b. The contractor shall wet clean and/or HEPA vacuum all non-removable non- asbestos items such as radiators and suspended light fixtures in the work area, including built-in equipment; and shall cover with two layers of polyethylene sheeting taped securely in place;
c. The contractor shall detach and wet clean removable electrical, heating, and ventilating equipment and other items, which may be connected to the asbestos surfaces. These items shall be removed from the work area and returned and reattached to their proper place when the work area has been decontaminated and final air testing has provided satisfactory results.
d. The contractor shall seal all floor, wall, and ceiling penetrations with suitable material such as expanding foam insulation before covering the surfaces with polyethylene sheeting. The contractor then shall seal all openings between the work area and uncontaminated areas including but not limited to, windows, doorways, elevator openings, skylights, corridor entrances, floor and sink drains, air ducts, grills, grates and diffusers with critical barriers consisting of two layers of polyethylene sheeting taped securely in place or stapled or fastened by spray-on adhesives, glue beads, or horizontal wood battens or the equivalent. Floor drains shall be sealed individually and then covered as all other floor surfaces with two layers of polyethylene sheeting. Separation barriers may be constructed to support the critical barriers. Separation barriers shall not black any required means of egress;
NYC-WTC 000104860
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000128550
Asbestos inspection report notification form submitted to NYC DEP for 102-104 Greenwich Street.
17 shared non-person entities · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000154680
Application form submitted to the Department of Environmental Protection for notification of an asbestos inspection project.
10 shared non-person entities · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000112116
NYC DEP emergency notification form documenting an urgent asbestos abatement situation at 250 Vesey Place requiring immediate action.
10 shared non-person entities · similarity 0.971
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125579
Technical specifications document prepared for asbestos abatement work at the 130 Cedar Street site.
11 shared non-person entities · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000135560
Application for permits regarding exterior remediation work at World Trade Center vicinity buildings.
6 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗14 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155525
Initial draft of the comprehensive scope of work required to safely clean 114 Liberty Street following environmental damage.
14 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000098577
Contract specifications outlining site decontamination and asbestos disposal procedures for 53 Park Place.
9 shared non-person entities · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗13 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗13 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107379
Formal request by a resident for the Department of Environmental Protection to perform cleaning and monitoring work at their apartment.
7 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000127792
NYC DEP Asbestos Project Notification form for abatement activities at a facility in the Phase 1 Decontamination Plan binder.
7 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000146129
Correspondence from NYC Corporation Counsel providing comments on excerpts of a draft EPA evaluation report regarding the WTC response.
Cited alongside this record in an Ask answer
NYC-WTC_000149199
Department of Environmental Protection advisory letter dated October 25, 2001, addressed to residents of Lower Manhattan.
Cited alongside this record in an Ask answer
NYC-WTC_000106110
Department of Environmental Protection advisory concerning air quality for building owners south of 14th Street following the WTC collapse.
Cited alongside this record in an Ask answer
NYC-WTC_000128550
Asbestos inspection report notification form submitted to NYC DEP for 102-104 Greenwich Street.
Cited alongside this record in an Ask answer
NYC-WTC_000142697
Report detailing air quality monitoring efforts and health precautions for residents regarding dust and smoke exposure.
Cited alongside this record in an Ask answer