NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 02/201 WARREN STREET Block: 16 Lot: 220
Document / 25 pages

Remediation plan cover page, 30 Warren Street, January 2006

Machine-extracted title · confidence 85%

Cover page for a remediation and deconstruction plan prepared for the State of New York.

NYC-WTC_000096519–000096543

Folder label: “201 WARREN STREET Block: 16 Lot: 220

Page image
Scanned page image, NYC-WTC_000096531
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Regulatory Submittal Part IV- Waste Sampling & Management Plan Fiterman Hall 30 West Broadway, New York. New York Airtek Project 05-0867 — January 10, 2006

asbestos-contaminated, will be used as the basis for the Waste Profile for the particular waste stream.

6.0 Waste Packaging and Storage

Locked waste storage areas will be established in the southeast corner of the first floor of the Building to accommodate both categorized waste awaiting transport, and suspect waste awaiting analyses (See Attachment C). Storage areas will be plasticized, and any liquid storage will have secondary containment. Incompatible waste streams will be segregated, and waste labeling and signage will be in strict accordance with regulations. Within the storage area, posted signs, labeled accumulation start dates, labeled description of the waste, aisle space, proper segregation of incompatible and or/ignitable waste, etc. will be inspected on a daily basis by the Environmental Consultant. Statutory waste volume and holding times shall not be exceeded.

All containers on site will have proper labeling, which includes information such as waste type and accumulation date.

6.1 Asbestos Waste

Waste containing asbestos, containerized and labeled per NYS ICR 56 may be stored in an area maintained under a negative pressure ventilation system. ACM packaging and waste decontamination procedures will be in accordance with NYS Industrial Code Rule 56. Containers holding asbestos waste will be inspected daily to ensure no visible emissions of asbestos dust in the air or breaks in the container.

Storage of asbestos waste will not exceed 50 cubic yards. Authorization from the New York City Department of Sanitation (NYCDOS) and additional requirements, per code, will be required if accumulation of asbestos is anticipated to be greater than 50 cubic yards.

6.2 PPE and Remediation Process Consumables

PPE and Remediation Process Consumables will be packaged, labeled and stored as ACM waste as a minimum, and based on the results of the dust characterization study. In addition, packaging and Storage of these wastes will be subject to the results of representative sampling conducted according to Section 4.2.

6.3 Hazardous Waste

Hazardous waste will be placed in containers made of or lined with materials that will not react with, and are otherwise compatible with, the hazardous waste to be stored so that the ability of the container to contain the waste is not impaired (e.g., USDOT approved drums, bags, roll-off

13

NYC-WTC 000096531

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000096531Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →