NYC 9/11 Public Portal Document
Regulatory Submittal Part IV- Waste Sampling & Management Plan
Fiterman Hall 30 West Broadway, New York, New York
Airtek Project 05-0867 — January 10, 2006
cresol (D026), nitrobenzene (D036), pentachlorophenol (D037), pyridine
(D038), 2,4,5-trichlorophenol (D041), and 2,4,6-trichlorophenol (D042).
— Pesticide toxic constituents - Method 8081A of "Test Methods for
Evaluating Solid Waste, Physical/Chemical Methods," EPA Publication SW-
846. Pesticide toxic constituents include chlordane (D020), endrin (DO12),
heptachlor and its epoxide (D031), lindane (DO 13), methoxychlor (DO 14), and
toxaphene (D015).
— Herbicide toxic constituents - Method 8151 A of "Test Methods for
Evaluating Solid Waste, Physical/Chemical Methods," EPA Publication SW-
846. Herbicide toxic constituents include 2,4-D (DO16) and 2,4,5-TP (also
known as Silvex, DO17).
— Mercury (DO09) - Method 7470A (aqueous samples) of "Test Methods for
Evaluating Solid Waste, Physical/Chemical Methods," EPA Publication SW-
846.
— Metals/inorganics other than mercury - Method 6010B, or Method 6020 of
"Test Methods for Evaluating Solid Waste, Physical/Chemical Methods,"
EPA Publication SW-846. These constituents include arsenic (D004), barium
(DO05), cadmium (DO06), chromium (DO07), lead (D008), selenium (DO10),
and silver (DO11).
5.2 Ignitability
American Society of Testing Materials (ASTM) method D-93-79 or D-93-80 or
D-3278-78.
5.3 Corrosivity
Method 9045D or 9040C as set forth in "Test Methods for Evaluating Solid
Waste, Physical/Chemical Methods," EPA Publication SW-846.
5.4 Reactivity
7.3.3.2 or 7.3.4.2 of "Test Methods for Evaluating Solid Waste,
Physical/Chemical Methods," EPA Publication SW-846.
5.5 Total PCBs
SW-846 Method 8082, Analysis of Polychlorinated Biphenyls by Gas
Chromatography is specified by regulation for determining the concentration of
PCBs in wastes.
The results of RCRA characteristic analyses, the classification of the material
based on historical information, as well as the material's status as presumptively
12
NYC-WTC 000096530
OCR can misread numbers and units. Confirm readings against the page image before using them.