NYC 9/11 Public Portal Document
Regulatory Submittal Part IV- Waste Sampling & Management Plan
Fiterman Hall 30 West Broadway. New York, New York
Airtek Project 05-0867 — January 10, 2006
1.0 General
1.1 Objective
The objective of the Waste Sampling and Management Plan (WSMP) is to
characterize, manage, containerize, and legally transport and dispose of
waste streams that will be generated as part of the Fiterman Hall
Remediation & Deconstruction Project.
1.2. Background
Pei Cobb Freed & Partners, Architects, LLP (PCF-P) has engaged the
Environmental Consultant, Airtek Environmental Corp. (Airtek) on behalf
of the Dormitory Authority of the State of New York (DASNY) and the
City University of New York (CUNY) to prepare the WSMP in support of
the remediation and deconstruction of Fiterman Hall, located at 30 West
Broadway, New York, NY (the Building). This plan is in response to a
request by the WTC Regulators for a documented approach to the project,
and is Part IV of the Regulatory Submittal Package for the Project.
The Building was severely impacted by fallout from the events of
September 11, 2001. It is the Owner's intent to conduct remediation of
WTC-related contamination and abatement of in-place asbestos so that
conventional deconstruction activities can be completed.
1.3 Remediation Phase
The Remediation Phase of the project includes the removal of all interior
surfaces and non-structural elements within the Building, and the cleaning
and encapsulation of all remaining structural elements under containment.
The cleanup and abatement will be conducted so that the building can be
safely deconstructed to allow for redevelopment of the Site. The
Remediation Phase of the project will occur under negative pressure
containment and includes the following general categories: (a) the general
area cleanup of WTC dust and debris; (b) removal and disposal of
installed non-structural porous and non-porous building materials,
contents and components; (c) cleaning and salvage of certain installed
non-porous building equipment and components; (d) removal of building
materials containing asbestos which were present in the Building prior to
September 11, 2001; (e) packaging of asbestos and other regulated waste
including, but not limited to light bulbs, lighting ballasts, batteries,
mercury-containing thermostats, etc. at generation points; (f) movement of
containers to the decontamination unit and movement of decontaminated
containers to waste loading.
NYC-WTC 000095836